TY - JOUR
T1 - Influence of bronchial diameter change on the airflow dynamics based on a pressure-controlled ventilation system
AU - Ren, Shuai
AU - Cai, Maolin
AU - Shi, Yan
AU - Xu, Weiqing
AU - Zhang, Xiaohua Douglas
N1 - Publisher Copyright:
Copyright © 2017 John Wiley & Sons, Ltd.
PY - 2018/3
Y1 - 2018/3
N2 - Bronchial diameter is a key parameter that affects the respiratory treatment of mechanically ventilated patients. In this paper, to reveal the influence of bronchial diameter on the airflow dynamics of pressure-controlled mechanically ventilated patients, a new respiratory system model is presented that combines multigeneration airways with lungs. Furthermore, experiments and simulation studies to verify the model are performed. Finally, through the simulation study, it can be determined that in airway generations 2 to 7, when the diameter is reduced to half of the original value, the maximum air pressure (maximum air pressure in lungs) decreases by nearly 16%, the maximum flow decreases by nearly 30%, and the total airway pressure loss (sum of each generation pressure drop) is more than 5 times the original value. Moreover, in airway generations 8 to 16, with increasing diameter, the maximum air pressure, maximum flow, and total airway pressure loss remain almost constant. When the diameter is reduced to half of the original value, the maximum air pressure decreases by 3%, the maximum flow decreases by nearly 5%, and the total airway pressure loss increases by 200%. The study creates a foundation for improvement in respiratory disease diagnosis and treatment.
AB - Bronchial diameter is a key parameter that affects the respiratory treatment of mechanically ventilated patients. In this paper, to reveal the influence of bronchial diameter on the airflow dynamics of pressure-controlled mechanically ventilated patients, a new respiratory system model is presented that combines multigeneration airways with lungs. Furthermore, experiments and simulation studies to verify the model are performed. Finally, through the simulation study, it can be determined that in airway generations 2 to 7, when the diameter is reduced to half of the original value, the maximum air pressure (maximum air pressure in lungs) decreases by nearly 16%, the maximum flow decreases by nearly 30%, and the total airway pressure loss (sum of each generation pressure drop) is more than 5 times the original value. Moreover, in airway generations 8 to 16, with increasing diameter, the maximum air pressure, maximum flow, and total airway pressure loss remain almost constant. When the diameter is reduced to half of the original value, the maximum air pressure decreases by 3%, the maximum flow decreases by nearly 5%, and the total airway pressure loss increases by 200%. The study creates a foundation for improvement in respiratory disease diagnosis and treatment.
KW - airflow dynamics
KW - bronchial diameter change
KW - experiment
KW - respiratory system model
KW - simulation
UR - http://www.scopus.com/inward/record.url?scp=85031926890&partnerID=8YFLogxK
U2 - 10.1002/cnm.2929
DO - 10.1002/cnm.2929
M3 - Article
C2 - 28906592
AN - SCOPUS:85031926890
SN - 2040-7939
VL - 34
JO - International Journal for Numerical Methods in Biomedical Engineering
JF - International Journal for Numerical Methods in Biomedical Engineering
IS - 3
M1 - e2929
ER -