TY - JOUR
T1 - In-syringe dispersive liquid-liquid microextraction based on the solidification of ionic liquids for the determination of benzoylurea insecticides in water and tea beverage samples
AU - Wang, Huazi
AU - Hu, Lu
AU - Li, Wanzhen
AU - Yang, Xiaoling
AU - Lu, Runhua
AU - Zhang, Sanbing
AU - Zhou, Wenfeng
AU - Gao, Haixiang
AU - Li, Jing
N1 - Publisher Copyright:
© 2016 Elsevier B.V.
PY - 2017/1/1
Y1 - 2017/1/1
N2 - A novel in-syringe dispersive liquid-liquid microextraction based on the solidification of ionic liquids (in-syringe SIL-DLLME) was coupled with high-performance liquid chromatography-ultraviolet detector (HPLC-UVD) to detect five benzoylurea insecticides (BUs) in water and tea beverage samples. In this method, the hydrophobic ionic liquid [N8881][PF6] was formed in situ by the metathesis reaction between [N8881]Cl and the anion-exchange reagent KPF6 to extract the target analytes. The whole extraction procedure was performed in a syringe. The solidified extractant could be separated from the aqueous phase by exposing the emulsified extraction solution to an ice bath and then easily collected by squeezing out the aqueous phase through the prepared NWPP-based needle. Various parameters affecting the extraction efficiency, such as the amount of [N8881]Cl, the molar ratio of [N8881]Cl to KPF6, salt addition, cooling time, solution temperature, sample pH and sample volume, were evaluated. Under the optimized conditions, the proposed method was validated with satisfactory results: good linearities with coefficients of determination greater than 0.99 were obtained in the range of 2–500 µg L−1; the limits of detection varied between 0.29 and 0.59 µg L−1; the recoveries of the five benzoylurea insecticides ranged from 85.93% to 90.52%; and the intra-day (n=3) and inter-day (n=3) relative standard deviations were less than 5.36%. Finally, the proposed method was successfully used for the determination of BUs in real water and tea beverage samples.
AB - A novel in-syringe dispersive liquid-liquid microextraction based on the solidification of ionic liquids (in-syringe SIL-DLLME) was coupled with high-performance liquid chromatography-ultraviolet detector (HPLC-UVD) to detect five benzoylurea insecticides (BUs) in water and tea beverage samples. In this method, the hydrophobic ionic liquid [N8881][PF6] was formed in situ by the metathesis reaction between [N8881]Cl and the anion-exchange reagent KPF6 to extract the target analytes. The whole extraction procedure was performed in a syringe. The solidified extractant could be separated from the aqueous phase by exposing the emulsified extraction solution to an ice bath and then easily collected by squeezing out the aqueous phase through the prepared NWPP-based needle. Various parameters affecting the extraction efficiency, such as the amount of [N8881]Cl, the molar ratio of [N8881]Cl to KPF6, salt addition, cooling time, solution temperature, sample pH and sample volume, were evaluated. Under the optimized conditions, the proposed method was validated with satisfactory results: good linearities with coefficients of determination greater than 0.99 were obtained in the range of 2–500 µg L−1; the limits of detection varied between 0.29 and 0.59 µg L−1; the recoveries of the five benzoylurea insecticides ranged from 85.93% to 90.52%; and the intra-day (n=3) and inter-day (n=3) relative standard deviations were less than 5.36%. Finally, the proposed method was successfully used for the determination of BUs in real water and tea beverage samples.
KW - Benzoylurea insecticides
KW - Dispersive liquid-liquid microextraction
KW - Ionic liquids
KW - Solidification
KW - Syringe
UR - http://www.scopus.com/inward/record.url?scp=84994048435&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2016.10.035
DO - 10.1016/j.talanta.2016.10.035
M3 - Article
C2 - 27837881
AN - SCOPUS:84994048435
SN - 0039-9140
VL - 162
SP - 625
EP - 633
JO - Talanta
JF - Talanta
ER -