Improvement of the control algorithm of a servo-system for background projection system

Pei Ye Feng*, Ning Dong, Yu He Zhang

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

In order to improve the performance of a servo-system for background projection system, its multi-mode control algorithm is modified. A different tri-mode control algorithm is adopted according to different angles of rotation of the system. That is, a tri-mode rule which includes the saturation control, the square root control, the PID control + feed forward control and certain position offset is used for large angles. When the angle is small, the saturation control is replaced by the reverse square root control. Using this algorithm, the time spent for the system on rotating from -90° to 90°, which used to be 0. 6 s, has been shortened to 0. 2 s, and the maximum position error of the system made less than 0. 5 mrad at the premise of non-overshoot and no vibration.

Original languageEnglish
Pages (from-to)351-354
Number of pages4
JournalHe Jishu/Nuclear Techniques
Volume22
Issue number3
Publication statusPublished - 1999

Keywords

  • Control algorithm
  • Flight simulation
  • Servo-system

Fingerprint

Dive into the research topics of 'Improvement of the control algorithm of a servo-system for background projection system'. Together they form a unique fingerprint.

Cite this

Feng, P. Y., Dong, N., & Zhang, Y. H. (1999). Improvement of the control algorithm of a servo-system for background projection system. He Jishu/Nuclear Techniques, 22(3), 351-354.