T1 - Hybrid constraint optimization for 3D subcutaneous vein reconstruction by near-infrared images
AU - Wu, Chan
AU - Yang, Jian
AU - Zhu, Jianjun
AU - Cong, Weijian
AU - Ai, Danni
AU - Song, Hong
AU - Liang, Xiaohui
AU - Wang, Yongtian
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/9
Y1 - 2018/9
N2 - Background and objective: The development of biometric identification technology and intelligent medication has enabled researchers to analyze subcutaneous veins from near-infrared images. However, the stereo reconstruction of subcutaneous veins has not been well studied, and the results are difficult to utilize in clinical practice. Methods: We present a hybrid constraint optimization (HCO) matching algorithm for vein reconstruction to solve the matching failure problems caused by the incomplete segmentation of vein structures captured from different views. This algorithm initially introduces the existence of the epipolar and homography constraints in the subcutaneous vein matching. Then, the HCO matching algorithm of the vascular centerline is established by homography point-to-point matching, homography matrix optimization, and vascular section matching. Finally, the 3D subcutaneous vein is reconstructed on the basis of the principle of triangulation and system calibration parameters. Results: To validate the performance of the proposed matching method, we designed a series of experiments to evaluate the effectiveness of the hybrid constraint optimization method. The experiments were performed on simulated and real datasets. 42 real vascular images were analyzed on the basis of different matching strategies. Experimental result shows that the matching accuracy increased significantly with the proposed optimization matching method. To calculate the reconstruction accuracy, we reconstructed seven simulated cardboards and measured 10 vascular distances in each simulated cardboard. The average vascular distance error of each simulated image was within 1.0 mm, and the distance errors of 75% feature points were less than 1.5 mm. Also, we printed a 3D simulated vein model to improve the illustration of this system. The reconstruction error extends from −3.58 mm to 1.94 mm with a standard deviation of 0.68 mm and a mean of 0.07 mm. Conclusions: The algorithm is validated in terms of homography optimization, matching efficiency, and simulated vascular reconstruction error. The experimental results demonstrate that the veins captured from the left and right views can be accurately matched through the proposed algorithm.
AB - Background and objective: The development of biometric identification technology and intelligent medication has enabled researchers to analyze subcutaneous veins from near-infrared images. However, the stereo reconstruction of subcutaneous veins has not been well studied, and the results are difficult to utilize in clinical practice. Methods: We present a hybrid constraint optimization (HCO) matching algorithm for vein reconstruction to solve the matching failure problems caused by the incomplete segmentation of vein structures captured from different views. This algorithm initially introduces the existence of the epipolar and homography constraints in the subcutaneous vein matching. Then, the HCO matching algorithm of the vascular centerline is established by homography point-to-point matching, homography matrix optimization, and vascular section matching. Finally, the 3D subcutaneous vein is reconstructed on the basis of the principle of triangulation and system calibration parameters. Results: To validate the performance of the proposed matching method, we designed a series of experiments to evaluate the effectiveness of the hybrid constraint optimization method. The experiments were performed on simulated and real datasets. 42 real vascular images were analyzed on the basis of different matching strategies. Experimental result shows that the matching accuracy increased significantly with the proposed optimization matching method. To calculate the reconstruction accuracy, we reconstructed seven simulated cardboards and measured 10 vascular distances in each simulated cardboard. The average vascular distance error of each simulated image was within 1.0 mm, and the distance errors of 75% feature points were less than 1.5 mm. Also, we printed a 3D simulated vein model to improve the illustration of this system. The reconstruction error extends from −3.58 mm to 1.94 mm with a standard deviation of 0.68 mm and a mean of 0.07 mm. Conclusions: The algorithm is validated in terms of homography optimization, matching efficiency, and simulated vascular reconstruction error. The experimental results demonstrate that the veins captured from the left and right views can be accurately matched through the proposed algorithm.
KW - Matching
KW - Near-infrared
KW - Stereo reconstruction
KW - Subcutaneous vein
UR - http://www.scopus.com/inward/record.url?scp=85048739812&partnerID=8YFLogxK
U2 - 10.1016/j.cmpb.2018.06.008
DO - 10.1016/j.cmpb.2018.06.008
M3 - Article
C2 - 30119847
AN - SCOPUS:85048739812
SN - 0169-2607
VL - 163
SP - 123
EP - 133
JO - Computer Methods and Programs in Biomedicine
JF - Computer Methods and Programs in Biomedicine
ER -