TY - JOUR
T1 - Fast and accurate automated recognition of the dominant cells from fecal images based on Faster R-CNN
AU - Zhang, Jing
AU - Wang, Xiangzhou
AU - Ni, Guangming
AU - Liu, Juanxiu
AU - Hao, Ruqian
AU - Liu, Lin
AU - Liu, Yong
AU - Du, Xiaohui
AU - Xu, Fan
N1 - Publisher Copyright:
© 2021, The Author(s).
PY - 2021/12
Y1 - 2021/12
N2 - Fecal samples can easily be collected and are representative of a person’s current health state; therefore, the demand for routine fecal examination has increased sharply. However, manual operation may pollute the samples, and low efficiency limits the general examination speed; therefore, automatic analysis is needed. Nevertheless, recognition exhaustion time and accuracy remain major challenges in automatic testing. Here, we introduce a fast and efficient cell-detection algorithm based on the Faster-R-CNN technique: the Resnet-152 convolutional neural network architecture. Additionally, a region proposal network and a network combined with principal component analysis are proposed for cell location and recognition in microscopic images. Our algorithm achieved a mean average precision of 84% and a 723 ms detection time per sample for 40,560 fecal images. Thus, this approach may provide a solid theoretical basis for real-time detection in routine clinical examinations while accelerating the process to satisfy increasing demand.
AB - Fecal samples can easily be collected and are representative of a person’s current health state; therefore, the demand for routine fecal examination has increased sharply. However, manual operation may pollute the samples, and low efficiency limits the general examination speed; therefore, automatic analysis is needed. Nevertheless, recognition exhaustion time and accuracy remain major challenges in automatic testing. Here, we introduce a fast and efficient cell-detection algorithm based on the Faster-R-CNN technique: the Resnet-152 convolutional neural network architecture. Additionally, a region proposal network and a network combined with principal component analysis are proposed for cell location and recognition in microscopic images. Our algorithm achieved a mean average precision of 84% and a 723 ms detection time per sample for 40,560 fecal images. Thus, this approach may provide a solid theoretical basis for real-time detection in routine clinical examinations while accelerating the process to satisfy increasing demand.
UR - http://www.scopus.com/inward/record.url?scp=85105854988&partnerID=8YFLogxK
U2 - 10.1038/s41598-021-89863-4
DO - 10.1038/s41598-021-89863-4
M3 - Article
C2 - 33990662
AN - SCOPUS:85105854988
SN - 2045-2322
VL - 11
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 10361
ER -