Experimental study on the ignition time of electric heaters with thermal insulation structure

Pengliang Li, Zhenyi Liu*, Mingzhi Li, Yao Zhao, Xuan Li, Ruiyan Sun

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

10 Citations (Scopus)

Abstract

Ignition is one of the most important techniques used to ignite crude oil during the in-situ combustion process. However, one problem with this process is that the ignition time is long. To address this problem, this study provides a solution by using a thermal insulation structure consisting of three layers placed inside an electric heater. To investigate the performance of the thermal insulation structure, combustion tube experiments were conducted over a range of air injection rates of 1 L/min to 5 L/min at ambient pressure. The experimental results demonstrated that the average diminution of heat loss is about 52.68% and the time required to ignite the oil reservoir was shortened by approximately 20 min. Therefore, the ignition energy was saved by using the thermal insulation structure. Furthermore, the ignition effect was also strongly influenced by the air injection rate. The maximum temperature increase and front combustion propagation speed increased with the increase of the air injection rate. In this study, the better air injection rate was 3 L/min. Under this condition, not only can the best ignition effect be guaranteed but also stable propagation of the combustion front can be ensured.

Original languageEnglish
Pages (from-to)855-862
Number of pages8
JournalEnergy
Volume160
DOIs
Publication statusPublished - 1 Oct 2018

Keywords

  • Air injection rate
  • Electrical ignition
  • Heat loss
  • Ignition time
  • Thermal insulation structure

Fingerprint

Dive into the research topics of 'Experimental study on the ignition time of electric heaters with thermal insulation structure'. Together they form a unique fingerprint.

Cite this