TY - JOUR
T1 - Deep eutectic solvent-based ultrasound-assisted dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography for the determination of ultraviolet filters in water samples
AU - Wang, Huazi
AU - Hu, Lu
AU - Liu, Xinya
AU - Yin, Shujun
AU - Lu, Runhua
AU - Zhang, Sanbing
AU - Zhou, Wenfeng
AU - Gao, Haixiang
N1 - Publisher Copyright:
© 2017
PY - 2017/9/22
Y1 - 2017/9/22
N2 - In the present study, a simple and rapid sample preparation method designated ultrasound-assisted dispersive liquid-liquid microextraction based on a deep eutectic solvent (DES) followed by high-performance liquid chromatography with ultraviolet (UV) detection (HPLC-UVD) was developed for the extraction and determination of UV filters from water samples. The model analytes were 2,4-dihydroxybenzophenone (BP-1), benzophenone (BP) and 2-hydroxy-4-methoxybenzophenone (BP-3). The hydrophobic DES was prepared by mixing trioctylmethylammonium chloride (TAC) and decanoic acid (DecA). Various influencing factors (selection of the extractant, amount of DES, ultrasound duration, salt addition, sample volume, sample pH, centrifuge rate and duration) on UV filter recovery were systematically investigated. Under optimal conditions, the proposed method provided good recoveries in the range of 90.2–103.5% and relative standard deviations (inter-day and intra-day precision, n = 5) below 5.9%. The enrichment factors for the analytes ranged from 67 to 76. The limits of detection varied from 0.15 to 0.30 ng mL−1, depending on the analytes. The linearities were between 0.5 and 500 ng mL−1 for BP-1 and BP and between 1 and 500 ng mL−1 for BP-3, with coefficients of determination greater than 0.99. Finally, the proposed method was applied to the determination of UV filters in swimming pool and river water samples, and acceptable relative recoveries ranging from 82.1 to 106.5% were obtained.
AB - In the present study, a simple and rapid sample preparation method designated ultrasound-assisted dispersive liquid-liquid microextraction based on a deep eutectic solvent (DES) followed by high-performance liquid chromatography with ultraviolet (UV) detection (HPLC-UVD) was developed for the extraction and determination of UV filters from water samples. The model analytes were 2,4-dihydroxybenzophenone (BP-1), benzophenone (BP) and 2-hydroxy-4-methoxybenzophenone (BP-3). The hydrophobic DES was prepared by mixing trioctylmethylammonium chloride (TAC) and decanoic acid (DecA). Various influencing factors (selection of the extractant, amount of DES, ultrasound duration, salt addition, sample volume, sample pH, centrifuge rate and duration) on UV filter recovery were systematically investigated. Under optimal conditions, the proposed method provided good recoveries in the range of 90.2–103.5% and relative standard deviations (inter-day and intra-day precision, n = 5) below 5.9%. The enrichment factors for the analytes ranged from 67 to 76. The limits of detection varied from 0.15 to 0.30 ng mL−1, depending on the analytes. The linearities were between 0.5 and 500 ng mL−1 for BP-1 and BP and between 1 and 500 ng mL−1 for BP-3, with coefficients of determination greater than 0.99. Finally, the proposed method was applied to the determination of UV filters in swimming pool and river water samples, and acceptable relative recoveries ranging from 82.1 to 106.5% were obtained.
KW - Deep eutectic solvent
KW - Dispersive liquid-liquid microextraction
KW - HPLC-UVD
KW - UV filters
UR - http://www.scopus.com/inward/record.url?scp=85028065620&partnerID=8YFLogxK
U2 - 10.1016/j.chroma.2017.07.073
DO - 10.1016/j.chroma.2017.07.073
M3 - Article
C2 - 28818328
AN - SCOPUS:85028065620
SN - 0021-9673
VL - 1516
SP - 1
EP - 8
JO - Journal of Chromatography A
JF - Journal of Chromatography A
ER -