Correcting motion artifacts of heart for intravascular optical coherence tomography images

Danni Liu, Yana Liu, Yi Xin, Qin Li*

*Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Citation (Scopus)

Abstract

Cardiovascular disease is one of the major diseases that cause human death. Atherosclerotic plaque rupture is the main pathogenesis of cardiovascular disease, which leads to coronary heart disease, such as myocardial ischemia, myocardial infarction, internal carotid atherosclerosis and other cardiovascular and cerebrovascular diseases. Intravascular optical coherence tomography (IVOCT) plays an important role in the diagnosis and treatment of cardiovascular diseases because of its high speed and high resolution. In the current various imaging examination method, clinician evaluate the coronary atherosclerotic plaque structural change by using intravascular ultrasound (IVUS) and IVOCT. IVOCT can provide micron size resolution, which is ten times of IVUS. However, the collected images have motion artifacts during the catheter is pulled back due to the periodic heartbeats. The artifacts would reduce the recognition accuracy of the plaques type and affect the preoperative planning and postoperative follow-up of percutaneous coronary intervention surgery. Based on the comprehensive analysis of the mechanism of motion artifacts and the characteristics of periodic cardiac motion, we designed a new algorithm to correct the rigid motion artifacts of coronary IVOCT images that caused by the heartbeat. This new algorithm can compensate part of translation to suppress of motion artifacts. Compared with the electrocardiogram control method, this algorithm does not need to discard the useful frames in the cardiac cycle, thus ensuring the integrity of the images.

Original languageEnglish
Title of host publicationOptics in Health Care and Biomedical Optics X
EditorsQingming Luo, Xingde Li, Ying Gu, Dan Zhu
PublisherSPIE
ISBN (Electronic)9781510639218
DOIs
Publication statusPublished - 2020
EventOptics in Health Care and Biomedical Optics X 2020 - Virtual, Online, China
Duration: 11 Oct 202016 Oct 2020

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume11553
ISSN (Print)0277-786X
ISSN (Electronic)1996-756X

Conference

ConferenceOptics in Health Care and Biomedical Optics X 2020
Country/TerritoryChina
CityVirtual, Online
Period11/10/2016/10/20

Keywords

  • Algorithm
  • Coronary atherosclerotic plaque
  • Correcting
  • Intravascular optical coherence tomography
  • Motion artifacts

Fingerprint

Dive into the research topics of 'Correcting motion artifacts of heart for intravascular optical coherence tomography images'. Together they form a unique fingerprint.

Cite this