TY - JOUR
T1 - Assessment of three different gadolinium-based regenerators in a rotary-type magnetic refrigerator
AU - Li, Zhenxing
AU - Shen, Jun
AU - Li, Ke
AU - Gao, Xinqiang
AU - Guo, Xiaohui
AU - Dai, Wei
N1 - Publisher Copyright:
© 2019 Elsevier Ltd
PY - 2019/5/5
Y1 - 2019/5/5
N2 - Room-temperature magnetic refrigeration is a recently developed, environment-friendly refrigeration technology. A rotary-type magnetic refrigerator has been built with a modified double Halbach permanent magnet array, which can provide an average magnetic field varying from 0.04 T to 1.50 T at a length of 100 mm. To evaluate the performance of AMRs with geometries, active magnetic regenerators (AMR) filled with gadolinium plates, spheres and flakes were respectively tested and compared. System performance such as temperature span, cooling power and pressure drop were investigated at different utilization factors and operating frequencies. The results revealed three AMRs performed quite differently. With larger specific heat transfer areas and smaller hydraulic diameters, AMRs filled with flakes/spheres provided better cooling performance. A maximum no-load temperature span of 14.8 K was obtained by flake-AMR with largest specific heat transfer areas and least filled mass. Sphere-AMR achieved a maximum temperature span of 10.8 K at a cooling power of 10 W among AMRs. With the same porosity and filled mass, sphere-AMR performed much better than plate-AMR, although the latter had a smaller pressure drop and associated pumping work.
AB - Room-temperature magnetic refrigeration is a recently developed, environment-friendly refrigeration technology. A rotary-type magnetic refrigerator has been built with a modified double Halbach permanent magnet array, which can provide an average magnetic field varying from 0.04 T to 1.50 T at a length of 100 mm. To evaluate the performance of AMRs with geometries, active magnetic regenerators (AMR) filled with gadolinium plates, spheres and flakes were respectively tested and compared. System performance such as temperature span, cooling power and pressure drop were investigated at different utilization factors and operating frequencies. The results revealed three AMRs performed quite differently. With larger specific heat transfer areas and smaller hydraulic diameters, AMRs filled with flakes/spheres provided better cooling performance. A maximum no-load temperature span of 14.8 K was obtained by flake-AMR with largest specific heat transfer areas and least filled mass. Sphere-AMR achieved a maximum temperature span of 10.8 K at a cooling power of 10 W among AMRs. With the same porosity and filled mass, sphere-AMR performed much better than plate-AMR, although the latter had a smaller pressure drop and associated pumping work.
KW - Active magnetic regenerators
KW - Experiments
KW - Gadolinium
KW - Magnetic refrigeration
KW - Magnetocaloric effect
UR - http://www.scopus.com/inward/record.url?scp=85062288178&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2019.02.100
DO - 10.1016/j.applthermaleng.2019.02.100
M3 - Article
AN - SCOPUS:85062288178
SN - 1359-4311
VL - 153
SP - 159
EP - 167
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
ER -