T1 - An experimental study of frost distribution and growth on finned tube heat exchangers used in air source heat pump units
AU - Zhang, Long
AU - Jiang, Yiqiang
AU - Dong, Jiankai
AU - Yao, Yang
AU - Deng, Shiming
N1 - Publisher Copyright:
© 2017 Elsevier Ltd
PY - 2018/3/5
Y1 - 2018/3/5
N2 - Many studies have been carried out on frost distribution and growth and their impacts on the performances of finned tube heat exchangers (FTHXs), the most commonly used structure for the outdoor coils of air source heat pump units. However, in almost all the studies, ethylene glycol water solution was used as refrigerant, which made the investigating of frost distribution and growth difficult due to the uneven temperature distribution along the tube length. Furthermore, quantitative experimental data for the frost distribution and growth on FTHXs have been insufficient. Therefore, in this paper, a quantitative experimental study using R410A as refrigerant on frost distribution and growth on two FTHXs with different fin pitches is reported. The study results demonstrated that the frost accumulated on an FTHX could be divided into two parts, one accumulated on the edge of windward fins and the other on the surfaces of fins and tubes. Furthermore, the ratios of the frost mass accumulated on the edge of windward fins to that on the entire FTHX surface were 13.7% (60 min frosting duration) and 12.5% (120 min frosting duration) for the two FTHXs, respectively. The frost thickness and average frost densities in these two parts were also evaluated and compared.
AB - Many studies have been carried out on frost distribution and growth and their impacts on the performances of finned tube heat exchangers (FTHXs), the most commonly used structure for the outdoor coils of air source heat pump units. However, in almost all the studies, ethylene glycol water solution was used as refrigerant, which made the investigating of frost distribution and growth difficult due to the uneven temperature distribution along the tube length. Furthermore, quantitative experimental data for the frost distribution and growth on FTHXs have been insufficient. Therefore, in this paper, a quantitative experimental study using R410A as refrigerant on frost distribution and growth on two FTHXs with different fin pitches is reported. The study results demonstrated that the frost accumulated on an FTHX could be divided into two parts, one accumulated on the edge of windward fins and the other on the surfaces of fins and tubes. Furthermore, the ratios of the frost mass accumulated on the edge of windward fins to that on the entire FTHX surface were 13.7% (60 min frosting duration) and 12.5% (120 min frosting duration) for the two FTHXs, respectively. The frost thickness and average frost densities in these two parts were also evaluated and compared.
KW - Experimental study
KW - Finned tube heat exchanger
KW - Frost distribution
KW - Frost growth
KW - Visual observation
UR - http://www.scopus.com/inward/record.url?scp=85039439549&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2017.12.047
DO - 10.1016/j.applthermaleng.2017.12.047
M3 - Article
AN - SCOPUS:85039439549
SN - 1359-4311
VL - 132
SP - 38
EP - 51
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
ER -