A recyclable tetracycline imprinted polymeric SPR sensor: In synergy with itaconic acid and methacrylic acid

Tehseen Nawaz, Muhammad Ahmad, Jieying Yu, Shiqi Wang, Tianxin Wei*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

9 Citations (Scopus)
Plum Print visual indicator of research metrics
  • Citations
    • Citation Indexes: 9
  • Captures
    • Readers: 11
see details

Abstract

A novel tetracycline (TC) imprinted polymer was prepared in visible lightviasynergy of dual functional group monomers methacrylic acid (MAA) and itaconic acid (IA) for the selective detection of TC in urine and milk samples. Surface plasmon resonance (SPR) and the reversible addition fragmentation chain transfer (RAFT) mechanism were employed in combination with 4-cyano-4-[(dodecylsulfanylthiocarbonyl)sulfanyl]pentanoic acid (CDTPA) in the presence of ethylene glycol dimethacrylate (EGDMA) as the cross-linker. In addition, the ratio of template, IA, MAA and EGDMA was optimized (0.8 : 0.3 : 5 : 9) by real time monitoringviaSPR. The surface of the TC imprinted sensor chip was characterized by contact angle measurements, Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscopy (SEM). The (IA-MAA@SPR)MIP sensor chip displayed a high adsorption capacity and selectivity in comparison to other analogues and non-imprinted polymer (NIP) based sensor chips. Through 7 adsorption-desorption cycles, the (IA-MAA@SPR)MIP sensor chip exhibited a good recoverability. These features suggested that the IA-MAA based sensor chip was an ideal candidate for the detection of TC. Consequently, within the concentration range of 1 × 10−13-1 × 10−7mol L−1, the reflectivity changesversusthe negative logarithm of concentrations presented excellent linearity;R2= 0.99. Based on a linear equation, the IA-MAA@SPR MIP sensor chip showed lower values for the limit of detection (LOD) and limit of quantification (LOQ)i.e.1.38 × 10−14mol L−1and 4.5 × 10−14mol L−1, respectively. Furthermore, the influence of the matrix on the sensor chip was successfully analyzed in real samples with satisfactory outcomes. Hence, IA-MAA based MIPs in combination with the SPR sensor chip demonstrated potential application prospects for rapid and effective sensing even in the complicated matrices.

Original languageEnglish
Pages (from-to)3102-3111
Number of pages10
JournalNew Journal of Chemistry
Volume45
Issue number6
DOIs
Publication statusPublished - 14 Feb 2021

Fingerprint

Dive into the research topics of 'A recyclable tetracycline imprinted polymeric SPR sensor: In synergy with itaconic acid and methacrylic acid'. Together they form a unique fingerprint.

Cite this

Nawaz, T., Ahmad, M., Yu, J., Wang, S., & Wei, T. (2021). A recyclable tetracycline imprinted polymeric SPR sensor: In synergy with itaconic acid and methacrylic acid. New Journal of Chemistry, 45(6), 3102-3111. https://doi.org/10.1039/d0nj05364c