T1 - A pulsed pinhole atmospheric pressure interface for simplified mass spectrometry instrumentation with enhanced sensitivity
AU - Wei, Yongzheng
AU - Bian, Cunjuan
AU - Ouyang, Zheng
AU - Xu, Wei
N1 - Publisher Copyright:
Copyright © 2015 John Wiley & Sons, Ltd.
PY - 2015/4/30
Y1 - 2015/4/30
N2 - Rationale A proof-of-concept pulsed pinhole atmospheric pressure interface, namely PP-API, was developed and characterized for mass spectrometry instrumentation. Methods The PP-API was analyzed and optimized theoretically with respect to gas flow rate, opening force and dimensions. A PP-API interfaced mass spectrometry system was then constructed and tested. Results As a discontinuous pressure interface, the PP-API allows efficient ion transfer from atmosphere pressure ionization sources to ion traps directly. Both nano-ESI and APCI ionization sources have been successfully integrated with the PP-API interface for the detection of volatile, organic, peptide and polymer samples. The use of multiple ionization sources has also been demonstrated to enhance signal intensity, as well as avoid charge competitions in ionization sources. Conclusions With simplified geometry and high ion transfer efficiency, this PP-API would enable miniaturized mass spectrometry systems with high sensitivity.
AB - Rationale A proof-of-concept pulsed pinhole atmospheric pressure interface, namely PP-API, was developed and characterized for mass spectrometry instrumentation. Methods The PP-API was analyzed and optimized theoretically with respect to gas flow rate, opening force and dimensions. A PP-API interfaced mass spectrometry system was then constructed and tested. Results As a discontinuous pressure interface, the PP-API allows efficient ion transfer from atmosphere pressure ionization sources to ion traps directly. Both nano-ESI and APCI ionization sources have been successfully integrated with the PP-API interface for the detection of volatile, organic, peptide and polymer samples. The use of multiple ionization sources has also been demonstrated to enhance signal intensity, as well as avoid charge competitions in ionization sources. Conclusions With simplified geometry and high ion transfer efficiency, this PP-API would enable miniaturized mass spectrometry systems with high sensitivity.
UR - http://www.scopus.com/inward/record.url?scp=84928956034&partnerID=8YFLogxK
U2 - 10.1002/rcm.7140
DO - 10.1002/rcm.7140
M3 - Article
C2 - 26406484
AN - SCOPUS:84928956034
SN - 0951-4198
VL - 29
SP - 701
EP - 706
JO - Rapid Communications in Mass Spectrometry
JF - Rapid Communications in Mass Spectrometry
IS - 8
ER -