N2 - A novel method based on hybrid energy storage system (HESS), composed of adiabatic compressed air energy storage (A-CAES) and flywheel energy storage system (FESS), to mitigate wind power fluctuations and augment wind power penetration is proposed in this paper. Wind power fluctuates in different frequencies, mainly divided into low and high frequency, which can be coped with by A-CAES and FESS respectively. To fit with low frequency fluctuation exhibiting large magnitude, A-CAES with multi-operating strategies is first proposed to widen operational ranges. Mathematical model of key components’ off-design performance is established. For a 49.5 MW wind farm in China, design and optimization of HESS are comprehensively investigated. More specifically, the selection of A-CAES system's key components, such as compressor and expander, and parameters of them are specified as well as the parameters of FESS. The key operating parameters of the HESS, when integrated with wind plant, are analyzed and the characteristics are revealed. The results indicate that by HESS, wind power with fluctuation within 0–49.5 MW (average 25.55 MW) can be stabilized to a steady electrical power output of 24.18 MW. The loss of wind power is 6.6%, far less than the wind power rejection rate 17.1% in China.
AB - A novel method based on hybrid energy storage system (HESS), composed of adiabatic compressed air energy storage (A-CAES) and flywheel energy storage system (FESS), to mitigate wind power fluctuations and augment wind power penetration is proposed in this paper. Wind power fluctuates in different frequencies, mainly divided into low and high frequency, which can be coped with by A-CAES and FESS respectively. To fit with low frequency fluctuation exhibiting large magnitude, A-CAES with multi-operating strategies is first proposed to widen operational ranges. Mathematical model of key components’ off-design performance is established. For a 49.5 MW wind farm in China, design and optimization of HESS are comprehensively investigated. More specifically, the selection of A-CAES system's key components, such as compressor and expander, and parameters of them are specified as well as the parameters of FESS. The key operating parameters of the HESS, when integrated with wind plant, are analyzed and the characteristics are revealed. The results indicate that by HESS, wind power with fluctuation within 0–49.5 MW (average 25.55 MW) can be stabilized to a steady electrical power output of 24.18 MW. The loss of wind power is 6.6%, far less than the wind power rejection rate 17.1% in China.
KW - Compressed air energy storage
KW - Flywheel energy storage
KW - Optimum design
KW - Wind power
KW - Wind power rejection rate
UR - http://www.scopus.com/inward/record.url?scp=85042717277&partnerID=8YFLogxK
U2 - 10.1016/j.renene.2018.02.058
DO - 10.1016/j.renene.2018.02.058
M3 - Article
AN - SCOPUS:85042717277
SN - 0960-1481
VL - 125
SP - 121
EP - 132
JO - Renewable Energy
JF - Renewable Energy
ER -