电极结构对负电晕放电Trichel脉冲及其电磁辐射场的影响

Translated title of the contribution: Effect of Electrode Structure on Trichel Pulse and Its Electromagnetic Radiation Field of Negative Corona Discharge

Chuang Wang, Xi Chen*, Xiyue Liang, Jialu Fu

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Corona discharge is a self-sustaining discharge which occurs in the uneven electric field, which can produce electromagnetic radiation field during the discharge process. The structure of discharge electrode is one of the key factors affecting the discharge of electromagnetic radiation field. In this paper, the effects of electrode characteristics on Trichel pulse current and its electromagnetic radiation field of negative corona discharge are studied. The effects of electrode tip radius and electrode spacing on discharge current and its electromagnetic radiation characteristics are studied through the combination of theory and experiment. The discharge electromagnetic radiation characteristics of a single electrode were analyzed theoretically. The results show that, with the increase in electrode tip radius, the amplitudes of Trichel pulse current increases and electromagnetic radiation field increase, and the frequency is unchanged. With the increase in electrode spacing, the current and electromagnetic radiation field characteristics are not affected when the discharge is in a stable state. The experimental results of Trichel pulse electromagnetic radiation field characteristics of a laboratory needle-plate discharge structure are consistent with the discharge characteristics of discharger.

Translated title of the contributionEffect of Electrode Structure on Trichel Pulse and Its Electromagnetic Radiation Field of Negative Corona Discharge
Original languageChinese (Traditional)
Pages (from-to)291-298
Number of pages8
JournalBinggong Xuebao/Acta Armamentarii
Volume41
DOIs
Publication statusPublished - Jun 2020

Fingerprint

Dive into the research topics of 'Effect of Electrode Structure on Trichel Pulse and Its Electromagnetic Radiation Field of Negative Corona Discharge'. Together they form a unique fingerprint.

Cite this