TY - JOUR
T1 - Numerical investigation on the effect of the cross-sectional aspect ratio of a rectangular cylinder in FIM on hydrokinetic energy conversion
AU - Zhang, Baoshou
AU - Wang, Keh Han
AU - Song, Baowei
AU - Mao, Zhaoyong
AU - Tian, Wenlong
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/12/15
Y1 - 2018/12/15
N2 - FIM (Flow Induced Motion) is a kind of widespread and high-energy phenomenon. In application, FIM could be used to harvest hydrokinetic energy from ocean/river currents. In this study, a spring-mounted rectangular cylinder were numerically investigated in a flow domain for the ranges of 7500 < Reynolds number <187500 (0.1 m/s < flow speed <2.5 m/s) to examine the effect of its cross-sectional aspect ratio on the FIM responses and hydrokinetic energy conversion. Results indicate that in general, high aspect ratio has a negative effect on FIM. When the aspect ratio increases from 1/6 to 1.5, the FIM amplitude is gradually suppressed. When the aspect ratio reaches up to 2.0, both VIV (Vortex Induced Vibration) and galloping won't occur at any flow speed. For energy harvesting, when the aspect ratio decreases from 2 to 1/4, the converted power shows the increasing trend. The maximum FIM energy conversion efficiency also accordingly increases to 15.5%. It should be noted that when the aspect ratio reduces to 1/6, the maximum power keeps the increasing trend; however, the total energy conversion efficiency is not further enhanced, which implies the optimal aspect ratio for energy harvesting is around 1/4.
AB - FIM (Flow Induced Motion) is a kind of widespread and high-energy phenomenon. In application, FIM could be used to harvest hydrokinetic energy from ocean/river currents. In this study, a spring-mounted rectangular cylinder were numerically investigated in a flow domain for the ranges of 7500 < Reynolds number <187500 (0.1 m/s < flow speed <2.5 m/s) to examine the effect of its cross-sectional aspect ratio on the FIM responses and hydrokinetic energy conversion. Results indicate that in general, high aspect ratio has a negative effect on FIM. When the aspect ratio increases from 1/6 to 1.5, the FIM amplitude is gradually suppressed. When the aspect ratio reaches up to 2.0, both VIV (Vortex Induced Vibration) and galloping won't occur at any flow speed. For energy harvesting, when the aspect ratio decreases from 2 to 1/4, the converted power shows the increasing trend. The maximum FIM energy conversion efficiency also accordingly increases to 15.5%. It should be noted that when the aspect ratio reduces to 1/6, the maximum power keeps the increasing trend; however, the total energy conversion efficiency is not further enhanced, which implies the optimal aspect ratio for energy harvesting is around 1/4.
KW - Energy conversion efficiency
KW - FIM (flow induced motion)
KW - Galloping
KW - Rectangular cylinder
KW - VIV (vortex induced vibration)
UR - http://www.scopus.com/inward/record.url?scp=85054691484&partnerID=8YFLogxK
U2 - 10.1016/j.energy.2018.09.138
DO - 10.1016/j.energy.2018.09.138
M3 - Article
AN - SCOPUS:85054691484
SN - 0360-5442
VL - 165
SP - 949
EP - 964
JO - Energy
JF - Energy
ER -