Leak point localization systerm for closed vessel based on infrared image processing

Ling Zhao*, Tao Wang, Guangzheng Peng, Tong Zhao

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

In this paper, a device for closed vessel's leaking localization is introduced based on infrared image processing. After the infrared thermography captured multi-frame infrared images of the closed vessel with cooling gas, each frame of the ROI region is processed by Gauss filtering. The suspected leak points are detected by hough circle detection method after their edges in the ROI are extracted by using canny edge operator. Finally, the appearance probability of the suspected leak point is used to determine a leaking point. Experiments show that the proposed method overcomes the disadvantage of infrared image's higher level noise effectively and is able to accurately localize the leak points.

Original languageEnglish
Pages (from-to)233-236
Number of pages4
JournalYi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument
Volume31
Issue number8 SUPPL.
Publication statusPublished - Aug 2010

Keywords

  • Canny operator
  • Hough circle detection
  • Infrared image
  • Leak localization

Fingerprint

Dive into the research topics of 'Leak point localization systerm for closed vessel based on infrared image processing'. Together they form a unique fingerprint.

Cite this