Abstract
A new approach of regulator flow characteristics measurement is presented: filling-for-once method. Its principle is to fill a tank through a tested regulator, and to abtain the flow characteristics of the regulator by analyzing the quasi-balance section during the filling process. By modeling and simulation of the method, and experimental investigation of the flow characteristics of a regulator AR20 and precise regulator IR2000 with this method, the method is proved to be of more efficiency, less air consumption and higher precision than the conventional method.
Original language | English |
---|---|
Pages (from-to) | 57-60 |
Number of pages | 4 |
Journal | Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering |
Volume | 43 |
Issue number | 9 |
DOIs | |
Publication status | Published - Sept 2007 |
Keywords
- Filling-for-once method
- Flow characteristics
- Regulator
Fingerprint
Dive into the research topics of 'Flow characteristics measurement of regulator based on one filling-for-once method'. Together they form a unique fingerprint.Cite this
Peng, G., Zhang, H., Gao, S., & Fan, W. (2007). Flow characteristics measurement of regulator based on one filling-for-once method. Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 43(9), 57-60. https://doi.org/10.3901/JME.2007.09.057