Wang, D., Fu, L., Wang, X., Gong, Z., Samuelson, S., Duan, C., Jia, H., Ma, J. S., & Xie, H. (2013). Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror. Journal of Biomedical Optics, 18(8), Article 086005. https://doi.org/10.1117/1.JBO.18.8.086005
Wang, Donglin ; Fu, Linlai ; Wang, Xin et al. / Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror. In: Journal of Biomedical Optics. 2013 ; Vol. 18, No. 8.
@article{10f90e92ed994fc0bee8c430b49dc734,
title = "Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror",
abstract = "A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8 × 0.8 mm2mirror plate and a 1.6 × 1.4 mm 2 device footprint. The diameter of the endoscopic probe is only 3.5 mm. The imaging rate of the SS-OCT system is 50 frames/s. OCT images of both human suspicious oral leukoplakia tissue and normal buccal mucosa were taken in vivo and compared. The OCT imaging result agrees well with the histopathological analysis.",
keywords = "microelectromechanical system mirror, optical coherence tomography, oral cancer",
author = "Donglin Wang and Linlai Fu and Xin Wang and Zhongjian Gong and Sean Samuelson and Can Duan and Hongzhi Jia and Ma, {Jun Shan} and Huikai Xie",
year = "2013",
month = aug,
doi = "10.1117/1.JBO.18.8.086005",
language = "English",
volume = "18",
journal = "Journal of Biomedical Optics",
issn = "1083-3668",
publisher = "SPIE",
number = "8",
}
Wang, D, Fu, L, Wang, X, Gong, Z, Samuelson, S, Duan, C, Jia, H, Ma, JS & Xie, H 2013, 'Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror', Journal of Biomedical Optics, vol. 18, no. 8, 086005. https://doi.org/10.1117/1.JBO.18.8.086005
Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror. / Wang, Donglin; Fu, Linlai; Wang, Xin et al.
In:
Journal of Biomedical Optics, Vol. 18, No. 8, 086005, 08.2013.
Research output: Contribution to journal › Article › peer-review
TY - JOUR
T1 - Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror
AU - Wang, Donglin
AU - Fu, Linlai
AU - Wang, Xin
AU - Gong, Zhongjian
AU - Samuelson, Sean
AU - Duan, Can
AU - Jia, Hongzhi
AU - Ma, Jun Shan
AU - Xie, Huikai
PY - 2013/8
Y1 - 2013/8
N2 - A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8 × 0.8 mm2mirror plate and a 1.6 × 1.4 mm 2 device footprint. The diameter of the endoscopic probe is only 3.5 mm. The imaging rate of the SS-OCT system is 50 frames/s. OCT images of both human suspicious oral leukoplakia tissue and normal buccal mucosa were taken in vivo and compared. The OCT imaging result agrees well with the histopathological analysis.
AB - A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8 × 0.8 mm2mirror plate and a 1.6 × 1.4 mm 2 device footprint. The diameter of the endoscopic probe is only 3.5 mm. The imaging rate of the SS-OCT system is 50 frames/s. OCT images of both human suspicious oral leukoplakia tissue and normal buccal mucosa were taken in vivo and compared. The OCT imaging result agrees well with the histopathological analysis.
KW - microelectromechanical system mirror
KW - optical coherence tomography
KW - oral cancer
UR - http://www.scopus.com/inward/record.url?scp=84886094172&partnerID=8YFLogxK
U2 - 10.1117/1.JBO.18.8.086005
DO - 10.1117/1.JBO.18.8.086005
M3 - Article
C2 - 23942630
AN - SCOPUS:84886094172
SN - 1083-3668
VL - 18
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
IS - 8
M1 - 086005
ER -
Wang D, Fu L, Wang X, Gong Z, Samuelson S, Duan C et al. Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror. Journal of Biomedical Optics. 2013 Aug;18(8):086005. doi: 10.1117/1.JBO.18.8.086005