Effects of La0.8Sr0.2Mn(Fe)O3-δ protective coatings on SOFC metallic interconnects

Changjing Fu*, Kening Sun, Derui Zhou

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

15 Citations (Scopus)

Abstract

SUS430 (16%-17% (mass fraction) Cr) can be used as interconnects for solid oxide fuel cells (SOFCs) that operate at lower temperatures (< 800°C). However, oxidation of steel can occur readily at elevated temperatures leading to the formation of Cr2O3 and spinel (Fe3O4) and thus greatly degrades the performance of the fuel cell. The aim of this work was to reduce oxide growth, in particular, the Cr2O3 phase, through the application of La0.8Sr0.2MnO3-δ (LSM20) and La0.8Sr0.2FeO3-δ (LSF20) coatings by atmospheric plasma spraying technology (APS). Oxide growth was characterized by using X-ray diffraction (XRD), scanning electron microscopy (SEM) with an energy dispersive X-ray (EDX) analyzer. During oxidation of fifty 20 h cycles at 800°C in air, the samples with coatings remained very stable, whereas significant spallation and weight loss were observed for the uncoated steel. LSF20 presents apparently advantages in reducing oxidation growth, interface resistance and inhibition of diffusion of chromium. After exposure in air at 800°C for 1000 h, the interfacial resistance of LSF20-coated alloy is lowered by more than 23 times to that of LSM20-coated layer.

Original languageEnglish
Pages (from-to)320-326
Number of pages7
JournalJournal of Rare Earths
Volume24
Issue number3
DOIs
Publication statusPublished - Jun 2006
Externally publishedYes

Keywords

  • Coatings
  • Metallic interconnects
  • Plasma spraying
  • Rare earths
  • Solid oxide fuel cells

Fingerprint

Dive into the research topics of 'Effects of La0.8Sr0.2Mn(Fe)O3-δ protective coatings on SOFC metallic interconnects'. Together they form a unique fingerprint.

Cite this