TY - JOUR
T1 - Detection of clenbuterol hydrochloride residuals in pork liver using a customized surface plasmon resonance bioanalyzer
AU - Hu, Jiandong
AU - Chen, Ruipeng
AU - Wang, Shun
AU - Wang, Tingting
AU - Zhao, Yuanyuan
AU - Li, Jianwei
AU - Hu, Xinran
AU - Liang, Hao
AU - Zhu, Juanhua
AU - Sun, Xiaohui
AU - Ma, Liuzheng
AU - Jiang, Min
N1 - Publisher Copyright:
© 2015 Hu et al.
PY - 2015/3/23
Y1 - 2015/3/23
N2 - A surface plasmon resonance (SPR) immunoassay with an immobilization of self-assembled molecular identification membrane for the detection of residual Clenbuterol Hydrochloride (CLB) in pork liver was systematically investigated and experimentally validated for its high performance. SPR immunoassay with a regular competitive inhibition assay cannot be directly verified to detect CLB residuals. In this study, the binding of Au film with mercaptopropionic acid was investigated using the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. After that, the immunoglobulin IgG of swine (SwIgG-CLB) was bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. The modified comprehensive analysis of how the membrane structure works was introduced together with the customized SPR bioanalyzer. In order to evaluate the performance of this biomembrane structure, the concentrations of CLBcontained solutions of 0 ng•mL-1, 10 ng•mL-1, 20 ng•mL-1, 33.3 ng•mL-1, and 40 ng•mL-1 were prepared by adding CLB reagents into the solutions of CLB antibody (Clenbuterol Hydrochloride Antibody, CLB-Ab), successively and then the response unit (RU) was measured individually. Using the data collected from the linear CCD array, the fitting curve was established with the R-Square value of 0.9929. Correspondingly, the recovery rate ranged from 88.48% to 103.21% was experimented and the limit of detection of CLB in 1.26 ng•mL-1 was obtained efficiently. It was concluded that the detection method associated with biomembrane properties is expected to contribute much to the determination of residual CLB in pork liver quantitatively by using the customized SPR bioanalyzer.
AB - A surface plasmon resonance (SPR) immunoassay with an immobilization of self-assembled molecular identification membrane for the detection of residual Clenbuterol Hydrochloride (CLB) in pork liver was systematically investigated and experimentally validated for its high performance. SPR immunoassay with a regular competitive inhibition assay cannot be directly verified to detect CLB residuals. In this study, the binding of Au film with mercaptopropionic acid was investigated using the known form of the strong S-Au covalent bonds formed by the chemical radical of the mercaptopropionic acid and the Au film. After that, the immunoglobulin IgG of swine (SwIgG-CLB) was bonded with the mercaptopropionic acid by covalent -CO-NH- amide bonding. The modified comprehensive analysis of how the membrane structure works was introduced together with the customized SPR bioanalyzer. In order to evaluate the performance of this biomembrane structure, the concentrations of CLBcontained solutions of 0 ng•mL-1, 10 ng•mL-1, 20 ng•mL-1, 33.3 ng•mL-1, and 40 ng•mL-1 were prepared by adding CLB reagents into the solutions of CLB antibody (Clenbuterol Hydrochloride Antibody, CLB-Ab), successively and then the response unit (RU) was measured individually. Using the data collected from the linear CCD array, the fitting curve was established with the R-Square value of 0.9929. Correspondingly, the recovery rate ranged from 88.48% to 103.21% was experimented and the limit of detection of CLB in 1.26 ng•mL-1 was obtained efficiently. It was concluded that the detection method associated with biomembrane properties is expected to contribute much to the determination of residual CLB in pork liver quantitatively by using the customized SPR bioanalyzer.
UR - http://www.scopus.com/inward/record.url?scp=84925813602&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0122005
DO - 10.1371/journal.pone.0122005
M3 - Article
C2 - 25799327
AN - SCOPUS:84925813602
SN - 1932-6203
VL - 10
JO - PLoS ONE
JF - PLoS ONE
IS - 3
M1 - e0122005
ER -