Abstract
Aiming at the requirement in the initiator's firing reliability, the upper limit of 100% p firing level and the confidence interval of the function margin were given on basis of an optimal experiment design for estimating 100% p firing level. Then, a qualification method for the firing reliability of initiator was provided. Simulation study shows that, based on the optimal experiment design with small sample size, the estimation of 100% p firing level is precise and the result of reliability qualification is reliable but conservative a little bit.
Original language | English |
---|---|
Pages (from-to) | 426-431 |
Number of pages | 6 |
Journal | Binggong Xuebao/Acta Armamentarii |
Volume | 32 |
Issue number | 4 |
Publication status | Published - Apr 2011 |
Keywords
- Firing reliability
- Initiator
- Optimal experiment design
- Reliability qualification test
Fingerprint
Dive into the research topics of 'A qualification test method for firing reliability of initiator with small samples'. Together they form a unique fingerprint.Cite this
Tian, Y. B., & Wang, D. P. (2011). A qualification test method for firing reliability of initiator with small samples. Binggong Xuebao/Acta Armamentarii, 32(4), 426-431.