N2 - Background: After nearly 20 years of service, beamline 1W1A at the Beijing Synchrotron Radiation Facility undergoes an upgrade. Methods: To keep the beam spot to its designed specifi cations and to address the challenges posed by the increasement of the storage ring beam current, a newly designed bending mechanism for the monochromator is installed. The experimental setup includes updated equipment such as a 6-circle diff ractometer, a 2-dimensional array detector, a closed-cycle cryostat system, and a grazing incidence wide-angle X-ray scattering experiment system. Furthermore, the control system and user data management software were enhanced to support these hardware updates. Results and Conclusion: These updates have provided the beamline with more flexible measurement modes and expanded the dimensionality of experimental data, allowing users to conduct in situ experiments over a wide range of sample temperatures. Benifiting from the upgrades, new experimental methods have become available, resultingin significant improvements in both efficiency and resolution.
AB - Background: After nearly 20 years of service, beamline 1W1A at the Beijing Synchrotron Radiation Facility undergoes an upgrade. Methods: To keep the beam spot to its designed specifi cations and to address the challenges posed by the increasement of the storage ring beam current, a newly designed bending mechanism for the monochromator is installed. The experimental setup includes updated equipment such as a 6-circle diff ractometer, a 2-dimensional array detector, a closed-cycle cryostat system, and a grazing incidence wide-angle X-ray scattering experiment system. Furthermore, the control system and user data management software were enhanced to support these hardware updates. Results and Conclusion: These updates have provided the beamline with more flexible measurement modes and expanded the dimensionality of experimental data, allowing users to conduct in situ experiments over a wide range of sample temperatures. Benifiting from the upgrades, new experimental methods have become available, resultingin significant improvements in both efficiency and resolution.
KW - 1W1A beamline
KW - Beijing Synchrotron Radiation Facility (BSRF)
KW - Monochromator
KW - Triangular silicon crystal
UR - https://www.scopus.com/pages/publications/105033570361
U2 - 10.1007/s41605-026-00665-6
DO - 10.1007/s41605-026-00665-6
M3 - Article
AN - SCOPUS:105033570361
SN - 2509-9930
VL - 10
SP - 750
EP - 758
JO - Radiation Detection Technology and Methods
JF - Radiation Detection Technology and Methods
IS - 4
ER -