A system for three-dimensional computed tomography of chemiluminescence was developed to measure flames over a large field angle. Nine gradient-index rods, with a 9 ×1 endoscope and only one camera are used. Its large field of view, simplicity, and low cost make it attractive for inner flow field diagnostics. To study the bokeh effect caused by the imaging system on reconstruction solutions, fluorescent beads were used to determine the blurring function. Experiments using a steady diffusion flame were conducted to validate the system. Three models, namely the clear-imaging, out-of-focus imaging, and deconvolution models, were utilized. Taking the bokeh effect into account, the results suggest that based on run-times the deconvolution model provides the best reconstruction accuracy without increasing computational time.