This paper studies the protective performance of polyurea-coated steel pipes and aramid fiber-wound steel pipes under the multi-physical field load of internal explosion by combining experiments with numerical simulation. The experimental results show that applying aramid fiber winding has a limited effect on improving the anti-explosion performance of steel pipes, while polyurea-coated steel pipes exhibit better anti-explosion performance under the coupled load of shock waves and fragments. Simulation analysis reveals the protective mechanism of composite structures in terms of energy absorption and stress distribution, providing a theoretical basis for the optimal design of blast-resistant vessels.