摘要
Relative humidity (RH) is one of the main environmental factors affecting the emission behaviours of formaldehyde from building materials. Meanwhile, the initial emittable concentration (Cm,0) is proved to be the most sensitive key parameter to the emission behaviours. However, there is no report on the relationship between RH and Cm,0. In this paper, Cm,0 of formaldehyde from a type of medium density fiberboard in RH range of 20%-85% were tested by the ventilated C-history method. Experimental results show that Cm,0 increased by 10 times when RH rising from 20% to 85%. A linear relationship between ln(Cm,0) and RH is obtained based on the experimental results. A correlation characterizing the association of emission rate and RH is also derived. With the correlations, the Cm,0 or emission rate different from test RH conditions can be conveniently obtained. This study should be useful for predicting the emission characteristics under varied RH conditions.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 59-66 |
| 页数 | 8 |
| 期刊 | Procedia Engineering |
| 卷 | 121 |
| DOI | |
| 出版状态 | 已出版 - 2015 |
| 活动 | 9th International Symposium on Heating, Ventilation and Air Conditioning, ISHVAC 2015 Joint with the 3rd International Conference on Building Energy and Environment, COBEE 2015 - Tianjin, 中国 期限: 12 7月 2015 → 15 7月 2015 |
学术指纹
探究 'The Impact of Relative Humidity on the Emission Behaviour of Formaldehyde in Building Materials' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver