TY - JOUR
T1 - Supersonic condensation CO2 heat pump for enhanced low-temperature heating of electric vehicles
AU - Ding, Hongbing
AU - Hu, Rui
AU - Wang, Shiwei
AU - Xie, Peng
N1 - Publisher Copyright:
© 2026 Elsevier Ltd.
PY - 2026/11
Y1 - 2026/11
N2 - Motivated by the low-temperature heating demand of electric vehicles, a transcritical CO2 heat pump integrated with a supersonic condensation and deposition chamber (SCDC) is investigated as a potential approach to reduce Joule-Thomson throttling loss and improve heating performance under cold climate conditions. However, the coupled behaviors of supersonic expansion, non-equilibrium condensation, droplet slip, and radial migration of high-pressure CO2 in the SCDC have not yet been clarified. A novel Euler-Lagrange condensation model considering droplet nucleation, growth inside SCDC was built. Meanwhile, the experimental platform was established to investigate the phase-change behavior of CO2 and the heating performance of SCDC system. The simulated axial pressure distribution and COP under the experimental validation conditions show good agreement with the experimental measurements. It reveals that increasing the swirl number to 0.38 raises the maximum swirl strength to 1.45, thereby enhancing droplet radial migration and wall deposition. As the inlet pressure increases from 4.0 to 6.0 MPa, the heterogeneous droplet diameter at the SCDC outlet decreases from 5.73 to 5.32 μm, and the homogeneous droplet diameter increases from 0.058 to 0.090 μm. Compared with the conventional heat pump, the supersonic condensation heat pump (SCHP) still maintains stable operation at −17.0 °C when pin = 4.0 MPa where JT-based heat pump (JTHP) fails. Under an ambient temperature of 3.15 °C, SCHP maintains COP range of 2.52 to 1.94 as the discharge pressure increases, which is higher than the corresponding 2.40 to 1.87 of the JTHP.
AB - Motivated by the low-temperature heating demand of electric vehicles, a transcritical CO2 heat pump integrated with a supersonic condensation and deposition chamber (SCDC) is investigated as a potential approach to reduce Joule-Thomson throttling loss and improve heating performance under cold climate conditions. However, the coupled behaviors of supersonic expansion, non-equilibrium condensation, droplet slip, and radial migration of high-pressure CO2 in the SCDC have not yet been clarified. A novel Euler-Lagrange condensation model considering droplet nucleation, growth inside SCDC was built. Meanwhile, the experimental platform was established to investigate the phase-change behavior of CO2 and the heating performance of SCDC system. The simulated axial pressure distribution and COP under the experimental validation conditions show good agreement with the experimental measurements. It reveals that increasing the swirl number to 0.38 raises the maximum swirl strength to 1.45, thereby enhancing droplet radial migration and wall deposition. As the inlet pressure increases from 4.0 to 6.0 MPa, the heterogeneous droplet diameter at the SCDC outlet decreases from 5.73 to 5.32 μm, and the homogeneous droplet diameter increases from 0.058 to 0.090 μm. Compared with the conventional heat pump, the supersonic condensation heat pump (SCHP) still maintains stable operation at −17.0 °C when pin = 4.0 MPa where JT-based heat pump (JTHP) fails. Under an ambient temperature of 3.15 °C, SCHP maintains COP range of 2.52 to 1.94 as the discharge pressure increases, which is higher than the corresponding 2.40 to 1.87 of the JTHP.
KW - Electric vehicles
KW - Euler-Lagrange condensation model
KW - Heat pump
KW - Low-temperature ambient conditions
KW - Supersonic condensation and deposition chamber
UR - https://www.scopus.com/pages/publications/105053777384
U2 - 10.1016/j.applthermaleng.2026.133598
DO - 10.1016/j.applthermaleng.2026.133598
M3 - Article
AN - SCOPUS:105053777384
SN - 1359-4311
VL - 308
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 133598
ER -