The COD degradation and decolourization of wastewater containing RDX was studied by the processes of UV/TiO2, UV/TiO2/H2O2 and UV/TiO2/Fenton in a circulating slurry photocatalytie reactor with a low-voltage mercury lamp. The results showed that the most efficient process was UV/TiO2/Fenton and the least was UV/TiO2. The efficiency of these treatment processes was obviously impacted by the initial COD of wastewater. When the initial COD was less than 2g/L, the COD and colourity could be up to effluent standard in 180min and 90min respectively.
源语言 | 英语 |
---|---|
页(从-至) | 266-269 |
页数 | 4 |
期刊 | Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology |
卷 | 27 |
期 | 3 |
出版状态 | 已出版 - 3月 2007 |