TY - JOUR
T1 - Study on capillary performance and heat transfer characteristics of composite material wicks at high heat flux
AU - Xu, Qing
AU - Tan, Si Cong
AU - Liu, Yu Ting
AU - Jiang, Yu Yan
AU - Guo, Cong
AU - Qu, Xiao
N1 - Publisher Copyright:
© 2026 Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
PY - 2026/11
Y1 - 2026/11
N2 - With the continuous increase in power density of portable electronic devices, the evaporator section of flat heat pipes and vapor chambers is increasingly challenged by the coupled limitations of the capillary limit and boiling limit under high heat flux conditions, manifested by insufficient liquid replenishment and vapor blockage induced by undesired boiling within the wick. Conventional homogeneous wicks inherently suffer from a trade-off between high capillary pressure and high permeability, and most existing composite wick designs rely on combining different capillary structures fabricated from a single material, while rarely addressing the coupling between capillary and boiling limits from the perspective of wick thermal conductivity. In this work, a novel composite-material wick is proposed to enable high heat flux transport by spatially decoupling the heat-flow path from the liquid-transport path using a low-thermal-conductivity interlayer. The wick consists of multilayer sintered copper wire meshes integrated with a hydrophilic, low-thermal-conductivity polyethylene terephthalate (PET) layer, forming a hierarchical structure with pronounced gradients in both thermal conductivity and pore size along the thickness direction. Visualization experiments confirm that the PET layer effectively suppresses undesired in-wick nucleate boiling and vapor trapping, thereby preserving permeability and sustaining liquid supply under high heat flux conditions. The composite wick raises the maximum stable heat flux from 34.1, 23.4 and 39.0 W/cm2 to at least 68.7, 55.6 and 48.4 W/cm2 for the 200-, 250- and 300-mesh evaporation layers, respectively, corresponding to an enhancement of up to 2.4 times. Decomposition of this enhancement shows that, for the 200 and 250 mesh layers, the gain originates predominantly from the preservation of effective permeability under two-phase conditions (blockage-factor ratios of 1.77 and 2.09) rather than from the modest increase in nominal permeability (13.8% and 13.4%), whereas for the 300-mesh layer the blockage-retention benefit vanishes because lateral vapor venting through the fine mesh becomes the dominant resistance. This study provides a design strategy for evaporator wicks in heat pipes and vapor chambers operating at high heat flux, together with a quantitative criterion for the minimum evaporation-layer permeability required for the strategy to be effective.
AB - With the continuous increase in power density of portable electronic devices, the evaporator section of flat heat pipes and vapor chambers is increasingly challenged by the coupled limitations of the capillary limit and boiling limit under high heat flux conditions, manifested by insufficient liquid replenishment and vapor blockage induced by undesired boiling within the wick. Conventional homogeneous wicks inherently suffer from a trade-off between high capillary pressure and high permeability, and most existing composite wick designs rely on combining different capillary structures fabricated from a single material, while rarely addressing the coupling between capillary and boiling limits from the perspective of wick thermal conductivity. In this work, a novel composite-material wick is proposed to enable high heat flux transport by spatially decoupling the heat-flow path from the liquid-transport path using a low-thermal-conductivity interlayer. The wick consists of multilayer sintered copper wire meshes integrated with a hydrophilic, low-thermal-conductivity polyethylene terephthalate (PET) layer, forming a hierarchical structure with pronounced gradients in both thermal conductivity and pore size along the thickness direction. Visualization experiments confirm that the PET layer effectively suppresses undesired in-wick nucleate boiling and vapor trapping, thereby preserving permeability and sustaining liquid supply under high heat flux conditions. The composite wick raises the maximum stable heat flux from 34.1, 23.4 and 39.0 W/cm2 to at least 68.7, 55.6 and 48.4 W/cm2 for the 200-, 250- and 300-mesh evaporation layers, respectively, corresponding to an enhancement of up to 2.4 times. Decomposition of this enhancement shows that, for the 200 and 250 mesh layers, the gain originates predominantly from the preservation of effective permeability under two-phase conditions (blockage-factor ratios of 1.77 and 2.09) rather than from the modest increase in nominal permeability (13.8% and 13.4%), whereas for the 300-mesh layer the blockage-retention benefit vanishes because lateral vapor venting through the fine mesh becomes the dominant resistance. This study provides a design strategy for evaporator wicks in heat pipes and vapor chambers operating at high heat flux, together with a quantitative criterion for the minimum evaporation-layer permeability required for the strategy to be effective.
KW - Composite wick
KW - High heat flux vapor chamber
KW - Thermal conductivity gradient
KW - Vapor blockage suppression
UR - https://www.scopus.com/pages/publications/105052617164
U2 - 10.1016/j.icheatmasstransfer.2026.112789
DO - 10.1016/j.icheatmasstransfer.2026.112789
M3 - Article
AN - SCOPUS:105052617164
SN - 0735-1933
VL - 180
JO - International Communications in Heat and Mass Transfer
JF - International Communications in Heat and Mass Transfer
M1 - 112789
ER -