TY - JOUR
T1 - Self-supervised 3D deep learning on preoperative contrast-enhanced computed tomography for predicting high pathologic nodal burden in esophageal squamous cell carcinoma
T2 - temporal and external multicohort validation
AU - Li, Qian
AU - Li, Yongxin
AU - Bai, Jing
AU - Zhang, Jinze
AU - Nie, Zhenkai
AU - Ren, Yanxin
AU - Li, Zhantao
AU - Guo, Jin
AU - Li, Meng
AU - Zhang, Tingting
AU - Liu, Xinbo
N1 - Publisher Copyright:
Copyright © 2026 Li, Li, Bai, Zhang, Nie, Ren, Li, Guo, Li, Zhang and Liu.
PY - 2026/6/11
Y1 - 2026/6/11
N2 - Background – Accurate preoperative identification of high nodal burden (pathologic N2 or N3; hereafter N2+) is important in esophageal squamous cell carcinoma, but contrast-enhanced computed tomography criteria based mainly on nodal size and morphology have limited sensitivity. Methods – In this retrospective multicohort study, 1, 060 consecutive patients with esophageal squamous cell carcinoma who underwent preoperative contrast-enhanced computed tomography and curative-intent esophagectomy with lymphadenectomy were enrolled from two centers. Center A contributed a development cohort (n = 612; train/validation/internal test, 428/92/92) and a temporally held-out cohort (n = 238), and Center B contributed an external test cohort (n = 210). A three-dimensional residual convolutional neural network encoder was pretrained on 3, 200 unlabeled chest computed tomography examinations using masked-volume reconstruction and then fine-tuned on tumor-centered volumes comprising the primary tumor plus a 5-mm margin. Results – The self-supervised model achieved area under the receiver operating characteristic curve values of 0.881 (95% confidence interval, 0.793–0.955) in the internal test cohort, 0.860 (95% confidence interval, 0.810–0.903) in the temporal cohort, and 0.860 (95% confidence interval, 0.810–0.906) in the external cohort. In the external cohort, sensitivity and specificity at the main operating point were 0.581 and 0.845 for the self-supervised model versus 0.339 and 0.784 for the guideline-inspired comparator. Calibration also improved with self-supervised pretraining (Brier score, 0.148; expected calibration error, 0.053). Conclusion – A contrast-enhanced computed tomography-only self-supervised three-dimensional model predicted high pathologic nodal burden in esophageal squamous cell carcinoma with robust temporal and external validation and showed numerically higher performance than a transparent computed tomography-only comparator. Calibrated risk estimates may help prioritize additional nodal workup when staging resources are limited or routine computed tomography findings are equivocal.
AB - Background – Accurate preoperative identification of high nodal burden (pathologic N2 or N3; hereafter N2+) is important in esophageal squamous cell carcinoma, but contrast-enhanced computed tomography criteria based mainly on nodal size and morphology have limited sensitivity. Methods – In this retrospective multicohort study, 1, 060 consecutive patients with esophageal squamous cell carcinoma who underwent preoperative contrast-enhanced computed tomography and curative-intent esophagectomy with lymphadenectomy were enrolled from two centers. Center A contributed a development cohort (n = 612; train/validation/internal test, 428/92/92) and a temporally held-out cohort (n = 238), and Center B contributed an external test cohort (n = 210). A three-dimensional residual convolutional neural network encoder was pretrained on 3, 200 unlabeled chest computed tomography examinations using masked-volume reconstruction and then fine-tuned on tumor-centered volumes comprising the primary tumor plus a 5-mm margin. Results – The self-supervised model achieved area under the receiver operating characteristic curve values of 0.881 (95% confidence interval, 0.793–0.955) in the internal test cohort, 0.860 (95% confidence interval, 0.810–0.903) in the temporal cohort, and 0.860 (95% confidence interval, 0.810–0.906) in the external cohort. In the external cohort, sensitivity and specificity at the main operating point were 0.581 and 0.845 for the self-supervised model versus 0.339 and 0.784 for the guideline-inspired comparator. Calibration also improved with self-supervised pretraining (Brier score, 0.148; expected calibration error, 0.053). Conclusion – A contrast-enhanced computed tomography-only self-supervised three-dimensional model predicted high pathologic nodal burden in esophageal squamous cell carcinoma with robust temporal and external validation and showed numerically higher performance than a transparent computed tomography-only comparator. Calibrated risk estimates may help prioritize additional nodal workup when staging resources are limited or routine computed tomography findings are equivocal.
KW - contrast-enhanced computed tomography
KW - deep learning
KW - esophageal squamous cell carcinoma
KW - external validation
KW - nodal staging
KW - risk prediction
KW - self-supervised learning
UR - https://www.scopus.com/pages/publications/105044420038
U2 - 10.3389/fmed.2026.1841260
DO - 10.3389/fmed.2026.1841260
M3 - Article
AN - SCOPUS:105044420038
SN - 2296-858X
VL - 13
JO - Frontiers in Medicine
JF - Frontiers in Medicine
ER -