跳到主要导航 跳到搜索 跳到主要内容

Research on performance measurement method of gas leak infrared imaging detection system

  • Jia Kun Li
  • , Wei Qi Jin*
  • , Xia Wang
  • , Xu Zhang
  • , Yang Liu
  • , Run Qiu Xia
  • *此作品的通讯作者
  • Beijing Institute of Technology

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

As a result of its significant advantages of high efficiency and remote imaging detection, gas leak infrared imaging detection technology has become one of the most effective means to detect gas leaks. This paper focuses on the performance measurement system of gas leak infrared imaging detection system. A novel minimum resolvable gas concentration (MRGC) evaluation method was proposed that was suitable for evaluating the performance of the passive gas leak infrared imaging detection system. The MRGC measurement system was designed and built. The measurement result, using ethylene as the target gas, and the minimum resolvable temperature difference (MRTD) curve were in good agreement, which sufficiently demonstrated the effectiveness of the MRGC performance evaluation method.

源语言英语
页(从-至)630-634
页数5
期刊Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology
卷36
期6
DOI
出版状态已出版 - 1 6月 2016