Reconstruction of MVCT Based on Irregular Portal Images Acquired by EPID

  • Zerui Chen
  • , Wendong Zhan*
  • , Qian Cao
  • , Junhai Wen
  • *此作品的通讯作者
  • Beijing Institute of Technology

科研成果: 书/报告/会议事项章节会议稿件同行评审

摘要

In the realm of radiation therapy, the precise positioning of patients constitutes a critical procedure, as it serves to ensure the accurate delivery of radiation doses and minimize the potential damage inflicted upon normal tissues. Accurate positioning not only enhances treatment efficacy but also significantly reduces the likelihood of adverse effects and complications. The Electronic Portal Imaging Device (EPID) is directly integrated into the gantry of a linear accelerator. By using the same source with the treatment, EPID eliminates the mechanical deviation issues inherent in traditional Cone Beam Computed Tomography (CBCT) systems and enables true real-time dose verification. However, applying images acquired by EPID to Mega Voltage Computed Tomography (MVCT) reconstruction and positioning verification still faces significant challenges. EPID captures irregular portal images during treatment, resulting in incomplete projection data, uneven projection angles, and even projection angles missing - all of which pose difficulties for MVCT reconstruction. Additionally, compared with CBCT systems, MVCT shows significantly lower soft-tissue contrast and signal-to-noise ratio. This paper proposes a new method for reconstructing MVCT from irregular portal images acquired by EPID. First, the two-dimensional irregular portal images synchronously collected by EPID during treatment are used as the original data source. After preprocessing, the ART reconstruction algorithm is applied to the pre-processed data, with TV regularization added during the reconstruction process for optimization. Results from the simulations confirm that the proposed algorithm is feasible, satisfactory reconstruction results can be obtained when λ=0.3 and paceTV=2.0. This method requires no additional operations and does not increase the patient's radiation dose. The reconstructed MVCT provides technical prerequisites for subsequent positioning verification.

源语言英语
主期刊名Proceedings - 2025 IEEE 2nd International Conference on Energy and Electrical Engineering, EEE 2025
编辑Mengqi Zhou
出版商Institute of Electrical and Electronics Engineers Inc.
ISBN(电子版)9798331518271
DOI
出版状态已出版 - 2025
已对外发布
活动2nd IEEE International Conference on Energy and Electrical Engineering, EEE 2025 - Nanchang, 中国
期限: 20 6月 202521 6月 2025

出版系列

姓名Proceedings - 2025 IEEE 2nd International Conference on Energy and Electrical Engineering, EEE 2025

会议

会议2nd IEEE International Conference on Energy and Electrical Engineering, EEE 2025
国家/地区中国
Nanchang
时期20/06/2521/06/25

指纹

探究 'Reconstruction of MVCT Based on Irregular Portal Images Acquired by EPID' 的科研主题。它们共同构成独一无二的指纹。

引用此