跳到主要导航 跳到搜索 跳到主要内容

Pseudo-inverse matrix method - A new method to deal with the adiabatic test data

  • Hua Qiao Zhu*
  • , Xin Ming Qian
  • , Zhi Min Fu
  • *此作品的通讯作者
  • Beijing Institute of Technology

科研成果: 期刊稿件文章同行评审

摘要

A pseudo-inverse matrix method to deal with the test data for accelerating rate calorimeter (ARC) is presented. The kinetic parameters of thermal decomposition for 4-nitrotoluene-2-sulfonic acid are calculated the pseudo-inverse matrix method. The reliability of the new method is tested by data simulation. It is showed that the pseudo-inverse matrix has advantage over other similar methods on adiabatic test data.

源语言英语
页(从-至)78-80
页数3
期刊Huozhayao Xuebao/Chinese Journal of Explosives and Propellants
26
1
出版状态已出版 - 2003

学术指纹

探究 'Pseudo-inverse matrix method - A new method to deal with the adiabatic test data' 的科研主题。它们共同构成独一无二的学术指纹。

引用此