TY - JOUR
T1 - Probing position-dependent electrolyte concentration in lithium-ion batteries using lithium metal reference electrodes
AU - Du, De Chen
AU - Xiao, Ye
AU - Ding, Xiao Qing
AU - Zhang, Shuo
AU - Yang, Shi Jie
AU - Yan, Chong
AU - Huang, Jia Qi
N1 - Publisher Copyright:
© 2026 Science Press and Dalian Institute of Chemical Physics, Chinese Academy of Sciences. Published by Elsevier B.V. and Science Press. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
PY - 2027/1
Y1 - 2027/1
N2 - Lithium-metal reference electrodes (REs) are widely used to decouple anode and cathode potentials, but their placement in practical lithium-ion pouch cells can introduce potential deviations of tens of millivolts. Here, we investigate the origins of the potential discrepancy between an RE positioned between the electrodes (RE-between) and an RE positioned outside the electrode stack (RE-outside) by combining three-electrode measurements, dynamic electrochemical impedance spectroscopy (DEIS), distribution of relaxation times (DRT) analysis, galvanostatic intermittent titration, and quantitative nuclear magnetic resonance (qNMR). qNMR measurements show that the electrolyte sampled from the side dead-volume region associated with RE-outside remains close to its initial concentration under the tested conditions. Pouch-cell relaxation and RE-relocation experiments, together with the kinetic asymmetry identified by DEIS/DRT, are consistent with concentration polarization in the internal electrode region; however, the electrolyte concentration at RE-between is inferred rather than directly measured. At 0.05 C, the measured iR-drop difference between the two RE configurations is small. The remaining potential discrepancy is consistent with unresolved, coupled contributions from the Nernst-potential shift at RE-between and the liquid junction potential, but these contributions are not independently quantified. We further formulate a conceptual relationship between RE potential differences and local electrolyte concentration. Its quantitative application requires independent determination of the concentration-dependent transference number and activity coefficient, as well as calibration using controlled concentration gradients. These results clarify the origin and limitations of placement-dependent RE measurements and provide a basis for future position-dependent electrolyte-sensing strategies in practical pouch cells.
AB - Lithium-metal reference electrodes (REs) are widely used to decouple anode and cathode potentials, but their placement in practical lithium-ion pouch cells can introduce potential deviations of tens of millivolts. Here, we investigate the origins of the potential discrepancy between an RE positioned between the electrodes (RE-between) and an RE positioned outside the electrode stack (RE-outside) by combining three-electrode measurements, dynamic electrochemical impedance spectroscopy (DEIS), distribution of relaxation times (DRT) analysis, galvanostatic intermittent titration, and quantitative nuclear magnetic resonance (qNMR). qNMR measurements show that the electrolyte sampled from the side dead-volume region associated with RE-outside remains close to its initial concentration under the tested conditions. Pouch-cell relaxation and RE-relocation experiments, together with the kinetic asymmetry identified by DEIS/DRT, are consistent with concentration polarization in the internal electrode region; however, the electrolyte concentration at RE-between is inferred rather than directly measured. At 0.05 C, the measured iR-drop difference between the two RE configurations is small. The remaining potential discrepancy is consistent with unresolved, coupled contributions from the Nernst-potential shift at RE-between and the liquid junction potential, but these contributions are not independently quantified. We further formulate a conceptual relationship between RE potential differences and local electrolyte concentration. Its quantitative application requires independent determination of the concentration-dependent transference number and activity coefficient, as well as calibration using controlled concentration gradients. These results clarify the origin and limitations of placement-dependent RE measurements and provide a basis for future position-dependent electrolyte-sensing strategies in practical pouch cells.
KW - Concentration polarization
KW - Detection discrepancy
KW - Mismatched reaction kinetics
KW - Placement
KW - Reference electrode
UR - https://www.scopus.com/pages/publications/105054340809
U2 - 10.1016/j.jechem.2026.09.053
DO - 10.1016/j.jechem.2026.09.053
M3 - Article
AN - SCOPUS:105054340809
SN - 2095-4956
VL - 124
SP - 922
EP - 934
JO - Journal of Energy Chemistry
JF - Journal of Energy Chemistry
ER -