摘要
We present the assembly and preliminary results of a prototype detector, which was developed to evaluate the performance of the Topmetal-II− for application in Soft X-ray Polarimeter (SXP). SXP is used to measure the polarization of X-rays emitted from randomly occurring gamma-ray bursts (GRBs) and other specific dense celestial bodies. The Topmetal-II− is a silicon pixel sensor designed to directly track charged particles. The test was conducted on a gas mixture of Ne and DME at 0.8 atm pressure, and the Topmetal-II− sensor was used to image the photoelectron tracks. Typical real X-ray tracks obtained under four conditions are presented in this paper. The modulation factor derived from the tracks of 100% polarized 4.5 keV X-rays reached ∼ 29% at ∼ 53% signal efficiency, with a residual modulation of the order of ∼ 2% for unpolarized 5.9 keV X-rays.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 165430 |
| 期刊 | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| 卷 | 1008 |
| DOI | |
| 出版状态 | 已出版 - 21 8月 2021 |
| 已对外发布 | 是 |
指纹
探究 'Preliminary test of topmetal-II− sensor for X-ray polarization measurements' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver