跳到主要导航 跳到搜索 跳到主要内容

Predictive computational framework to provide a digital twin for personalized cardiovascular medicine

  • Mengzhe Lyu*
  • , Ryo Torii*
  • , Ce Liang
  • , Xuehuan Zhang
  • , Xifu Wang
  • , Qiaoqiao Li
  • , Yiannis Ventikos
  • , Duanduan Chen*
  • *此作品的通讯作者
  • University College London
  • Siemens Healthineers Digital Technology (Shanghai) Co. Ltd.
  • Beijing Institute of Technology
  • Capital Medical University
  • University of International Business and Economics
  • Monash University

科研成果: 期刊稿件文章同行评审

摘要

Background: In percutaneous coronary intervention (PCI), the ability to predict post-PCI fractional flow reserve (FFR) and stented vessel informs procedural planning. However, highly precise and effective methods to quantitatively simulate coronary intervention are lacking. This study developed and validated a virtual coronary intervention (VCI) technique for non-invasive physiological and anatomical assessment of PCI. Methods: In this study, patients with substantial lesions (pre-PCI CT-FFR of less than 0.80) were enrolled. VCI framework was used to predict vessel reshape and post-PCI CT-FFR. The accuracy of predicted post-VCI CT-FFR, luminal cross-sectional area (CSA) and centreline curvature was validated with post-PCI computed tomography (CT) angiography datasets. Results: Overall, 30 patients are initially screened; 21 meet the inclusion criteria, and 9 patients (9 vessels) are included in the final analysis. The average PCI-simulation time is 24.92 ± 1.00 s on a single processor. The calculated post-PCI CT-FFR is 0.92 ± 0.09, whereas the predicted post-VCI CT-FFR is 0.90 ± 0.08 (mean difference: −0.02 ± 0.05 FFR units; limits of agreement: −0.08 to 0.05). Morphologically, the predicted CSA is 16.36 ± 4.41 mm² and the post-CSA is 17.91 ± 4.84 mm² (mean difference: −1.55 ± 1.89 mm²; limits of agreement: −5.22 to 2.12). The predicted centreline curvature across the stented segment (including ~2 mm proximal and distal margins) is 0.15 ± 0.04 mm⁻¹, while the post-PCI centreline curvature is 0.17 ± 0.03 mm⁻¹ (mean difference: −0.02 ± 0.06 mm⁻¹; limits of agreement: −0.12 to 0.09). Conclusions: The proposed VCI technique achieves non-invasive pre-procedural anatomical and physiological assessment of coronary intervention. The proposed model has the potential to optimize PCI pre-procedural planning and improve the safety and efficiency of PCI.

源语言英语
期刊论文编号370
期刊Communications Medicine
5
1
DOI
出版状态已出版 - 12月 2025
已对外发布

学术指纹

探究 'Predictive computational framework to provide a digital twin for personalized cardiovascular medicine' 的科研主题。它们共同构成独一无二的学术指纹。

引用此