跳到主要导航 跳到搜索 跳到主要内容

Note: Erosion of W-Ni-Fe and W-Cu alloy electrodes in repetitive spark gaps

  • Jiawei Wu
  • , Ruoyu Han
  • , Weidong Ding
  • , Aici Qiu
  • , Junping Tang

科研成果: 期刊稿件文章同行评审

摘要

A pair of W-Ni-Fe and W-Cu electrodes were tested under 100 kA level pulsed currents for 10 000 shots, respectively. Surface roughness and morphology characteristics of the two pairs of electrodes were obtained and compared. Experimental results indicated cracks divided the W-Cu electrode surface to polygons while the W-Ni-Fe electrode surface remained as a whole with pits and protrusions. Accordingly, the surface roughness of W-Ni-Fe electrodes increased to ∼3 μm while that of W-Cu electrodes reached ∼7 μm at the end of the test. The results reveal that the W-Ni-Fe alloy has a better erosion resistance and potential to be further applied in spark gaps.

源语言英语
文章编号026103
期刊Review of Scientific Instruments
89
2
DOI
出版状态已出版 - 1 2月 2018
已对外发布

指纹

探究 'Note: Erosion of W-Ni-Fe and W-Cu alloy electrodes in repetitive spark gaps' 的科研主题。它们共同构成独一无二的指纹。