跳到主要导航 跳到搜索 跳到主要内容

New test design method with small samples for reliability assessment of initiating explosive devices

科研成果: 期刊稿件文章同行评审

摘要

To assess the high reliability of initiating explosive device with small samples, the test design plan with small samples for initiating explosive devices was studied. Based on test information entropy, a new test design method was put forward. With this method, reliability of No.54 stab detonator which is used in head kindling organ of H/DR131 fuze was assessed. Twenty-two products were tested on the stress level of 4.5 cm and all fire. The assessment result is in agreement with the test result with 1800 samples. The product meets the reliability requirements with reliability of 0.999 at the confidence level of 0.90.

源语言英语
页(从-至)608-611
页数4
期刊Hanneng Cailiao/Chinese Journal of Energetic Materials
15
6
出版状态已出版 - 12月 2007