跳到主要导航 跳到搜索 跳到主要内容

Multi-dimensional attention-enhanced reconstruction for sparse-view CBCT

  • Yuhao Liu
  • , Wan Li
  • , Yiyuan Tao
  • , Tianling Lyu
  • , Yan Xi
  • , Yikun Zhang*
  • , Feng Wang*
  • , Pengcheng Zhang
  • , Jian Yang
  • , Yang Chen
  • *此作品的通讯作者
  • Southeast University, Nanjing
  • Capital Medical University
  • Zhejiang University of Technology
  • Ltd
  • North University of China
  • Beijing Institute of Technology

科研成果: 期刊稿件文章同行评审

摘要

Background: Cone-beam computed tomography (CBC T) is a high-resolution 3D imaging modality that has been widely applied clinically. However, it faces limitations due to the lag effect and concerns about radiation dose. While sparse-view CBCT can alleviate these problems by reducing the detector readout frequency and the exposure time, it introduces streak artifacts that can degrade image quality. Recent research has explored techniques for sparse-view CBCT reconstruction. Nevertheless, it remains an ongoing challenge to achieve improved image quality. Purpose: The purpose of this study is to eliminate the streak artifacts and recover image details with dual-domain deep learning networks. Methods: This study proposed a Multi-dimensional Attention-Enhanced reconstruction (MAE-Recon) algorithm for sparse-view CBCT. MAE-Recon consists of four key components: a linear interpolation module, a projection domain network, an FDK operator, and an image domain network. Firstly, the linear interpolation module generates an initial full-view projection. Subsequently, the projection domain network predicts high-quality projection data. The FDK operator then reconstructs CBCT images. Finally, the image domain network refines the reconstructed images. Considering the long-range dependency among projections and the information redundancy within features, this study introduces two plug-and-play modules for enhancement. Results: A real chest dataset and a simulated abdomen dataset were chosen for validation. The RMSE was reduced by (Formula presented.) (Formula presented.) and (Formula presented.) (Formula presented.), respectively, and the SSIM and PSNR scores were improved by 0.066, 0.009, and 4.62 dB, 1.44 dB on the two datasets. An ablation study was also performed. The improved RMSE, SSIM, and PSNR scores illustrate that the modules are practical and efficient. Conclusions: The MAE-Recon proposed in this study obtains high-quality images in sparse-view CBCT reconstruction, demonstrating the application potential.

源语言英语
期刊论文编号e70299
期刊Medical Physics
53
2
DOI
出版状态已出版 - 2月 2026
已对外发布

学术指纹

探究 'Multi-dimensional attention-enhanced reconstruction for sparse-view CBCT' 的科研主题。它们共同构成独一无二的学术指纹。

引用此