摘要
Millimeter-wave (MMW) imaging techniques have been developed for the detection of concealed weapons and plastic explosives carried on personnel at major transportation hubs and secure locations. The combination of frequency-modulated continuous-wave (FMCW) technology and MMW imaging techniques leads to wideband, compact, and cost-effective systems which are especially suitable for security detection. Cylindrical three-dimensional (3-D) imaging technique, with the ability of viewing multiple sides, is an extension of rectilinear 3-D imaging technique only viewing a single side. Due to the relatively long signal sweep time, the conventional stop-and-go approximation of the pulsed systems is not suitable for FMCW systems. Therefore, a 3-D backscattered signal model including the effects of the continuous motion within the signal duration time is developed for cylindrical imaging systems. Then, a holographic image reconstruction algorithm, with motion compensation, is presented and demonstrated by means of numerical simulations.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 519-537 |
| 页数 | 19 |
| 期刊 | Progress in Electromagnetics Research |
| 卷 | 128 |
| DOI | |
| 出版状态 | 已出版 - 2012 |
学术指纹
探究 'Modified cylindrical holographic algorithm for three-dimensional millimeterwave imaging' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver