TY - JOUR
T1 - MHz-rate fixed-WMS approach based on wavelength locking
AU - Zhang, Lin
AU - Sun, Jiachen
AU - Shao, Jiankun
N1 - Publisher Copyright:
© 2026 Elsevier B.V.
PY - 2026/12/15
Y1 - 2026/12/15
N2 - A MHz-rate fixed-wavelength modulation spectroscopy (fixed-WMS) approach based on 3 f wavelength locking is proposed. The third-harmonic (3 f) signal is employed as an error signal to lock the laser wavelength at the absorption center, thereby suppressing wavelength drift and improving the stability and interference resistance of fixed-WMS measurements. As a result, MHz-rate measurements beyond the limitation of conventional wavelength scanning are achieved. The approach is validated through low-pressure experiments, shock tube interference tests, and acetone pyrolysis measurements. During a 30 min continuous measurement, an average relative error of 0.31% is achieved, corresponding to an 87% reduction in measurement error compared with the unlocked condition. Under emission interference, optical path deflection, and particle obstruction conditions, the measurement errors are reduced from 9.4% to 2.3%, from 7.9% to 3.8%, and from 22.8% to 2.9%, respectively. Furthermore, CO concentration time histories with a bandwidth of 1.8 MHz are obtained during acetone (CH3COCH3) pyrolysis, showing good agreement with kinetic model predictions. To the best of our knowledge, this represents the highest measurement bandwidth achieved using mid-IR WMS diagnostics. This approach provides a robust solution for in-situ diagnostics of transient processes in harsh reactive flows.
AB - A MHz-rate fixed-wavelength modulation spectroscopy (fixed-WMS) approach based on 3 f wavelength locking is proposed. The third-harmonic (3 f) signal is employed as an error signal to lock the laser wavelength at the absorption center, thereby suppressing wavelength drift and improving the stability and interference resistance of fixed-WMS measurements. As a result, MHz-rate measurements beyond the limitation of conventional wavelength scanning are achieved. The approach is validated through low-pressure experiments, shock tube interference tests, and acetone pyrolysis measurements. During a 30 min continuous measurement, an average relative error of 0.31% is achieved, corresponding to an 87% reduction in measurement error compared with the unlocked condition. Under emission interference, optical path deflection, and particle obstruction conditions, the measurement errors are reduced from 9.4% to 2.3%, from 7.9% to 3.8%, and from 22.8% to 2.9%, respectively. Furthermore, CO concentration time histories with a bandwidth of 1.8 MHz are obtained during acetone (CH3COCH3) pyrolysis, showing good agreement with kinetic model predictions. To the best of our knowledge, this represents the highest measurement bandwidth achieved using mid-IR WMS diagnostics. This approach provides a robust solution for in-situ diagnostics of transient processes in harsh reactive flows.
KW - Anti-interference diagnostics
KW - Fixed-wavelength-modulation spectroscopy
KW - MHz-rate
KW - Wavelength locking
UR - https://www.scopus.com/pages/publications/105049621645
U2 - 10.1016/j.snb.2026.140803
DO - 10.1016/j.snb.2026.140803
M3 - Article
AN - SCOPUS:105049621645
SN - 0925-4005
VL - 469
JO - Sensors and Actuators B: Chemical
JF - Sensors and Actuators B: Chemical
M1 - 140803
ER -