T1 - Matched-Reference Dual-Detector Interferogram Classification for CH4/CO Sensing With Acquisition-Grouped Validation
AU - Wang, Lingzhi
AU - Zhang, Ruolan
AU - Duan, Shaoli
AU - Han, Xinheng
AU - Xin, Xiuli
AU - Feng, Xiaoxue
AU - Pan, Feng
N1 - Publisher Copyright:
© 2001-2012 IEEE.
PY - 2026
Y1 - 2026
N2 - In Fourier transform infrared (FTIR) gas monitoring, distinguishing methane (CH4), carbon monoxide (CO), and their cooccurrence is important because methane and carbon monoxide present distinct hazards associated with flammability and toxicity, respectively. This work presents a matched-reference dual-detector framework for categorical gas identification from interferogram-derived measurements rather than calibrated spectra. Condition-matched gas/block referencing across the co-acquired InSb and MCT branches is combined with acquisition-grouped learning and evaluation, preserving each parent acquisition as the independent decision unit. Evaluation used 64 independent CH4, CO, and physically acquired CH4+CO gas acquisitions at native 1, 2, and 4 cm−1 resolutions. The canonical protocol achieved exact-class/component-presence macro-F1 of 0.883/0.943, and the 2→4 cm−1 route achieved 0.807/0.897 on native 4 cm−1 targets. Under the same evaluation contract, the calibrated-radiance extremely randomized-tree baseline reached 0.547/0.678, while a same-acquisition control supported the contribution of matched physical referencing. These results support a physically referenced, acquisition-aware detector-domain route for categorical CH4/CO sensing under the measured conditions. The reported performance is limited to categorical identification of the physically measured gas and mixture conditions represented here and does not establish performance for arbitrary CH4/CO concentrations or mixing ratios.
AB - In Fourier transform infrared (FTIR) gas monitoring, distinguishing methane (CH4), carbon monoxide (CO), and their cooccurrence is important because methane and carbon monoxide present distinct hazards associated with flammability and toxicity, respectively. This work presents a matched-reference dual-detector framework for categorical gas identification from interferogram-derived measurements rather than calibrated spectra. Condition-matched gas/block referencing across the co-acquired InSb and MCT branches is combined with acquisition-grouped learning and evaluation, preserving each parent acquisition as the independent decision unit. Evaluation used 64 independent CH4, CO, and physically acquired CH4+CO gas acquisitions at native 1, 2, and 4 cm−1 resolutions. The canonical protocol achieved exact-class/component-presence macro-F1 of 0.883/0.943, and the 2→4 cm−1 route achieved 0.807/0.897 on native 4 cm−1 targets. Under the same evaluation contract, the calibrated-radiance extremely randomized-tree baseline reached 0.547/0.678, while a same-acquisition control supported the contribution of matched physical referencing. These results support a physically referenced, acquisition-aware detector-domain route for categorical CH4/CO sensing under the measured conditions. The reported performance is limited to categorical identification of the physically measured gas and mixture conditions represented here and does not establish performance for arbitrary CH4/CO concentrations or mixing ratios.
KW - Fourier transform infrared spectroscopy
KW - acquisition-grouped validation
KW - gas classification
KW - interferogram processing
KW - optical gas sensors
KW - sensor data processing