TY - JOUR
T1 - Large-dynamic-range Shack-Hartmann wavefront sensing based on fiducial-lenslet-anchored clustering
AU - Song, Yukun
AU - Dong, Bing
N1 - Publisher Copyright:
© 2026 Elsevier Ltd
PY - 2027/1
Y1 - 2027/1
N2 - The Shack-Hartmann wavefront sensor (SHWFS) is widely used for fast, accurate, and stable wavefront measurement, but its dynamic range is limited when focal spots move outside their corresponding subapertures. This paper presents a fiducial-lenslet-anchored clustering SHWFS (FLAC-SHWFS) for robust, large-dynamic-range wavefront measurement. The method combines clustering-based index assignment with fiducial lenslets embedded in the microlens array. Clustering assigns relative row and column indices to the detected spots, while the fiducial spots provide anchors that register these indices to the reference array, enabling reliable global spot-lenslet correspondence beyond local neighborhoods. Simulations show a mode-dependent improvement of the measurable dynamic range, substantial for the low-order Zernike modes Z4 and Z6, but marginal for Z9 and Z10. With the fiducial spot retained and correctly identified, the method achieved successful reconstruction in all 20 trials at each tested random spot-loss probability up to 35 %, and successful matching remained possible in individual trials at 65 % spot loss. The combined computation time of index assignment and morphology-based discrimination is 1.24 ms on average. Experiments using ophthalmic trial lenses verify the large-dynamic-range measurement capability. Further tests under 21.84 % structured spot loss produced by a spider-type aperture stop and 25 % random spot loss generated from a full-aperture spot image maintain reliable global matching, with residual RMS values of 0.159 λ and 0.048 λ, respectively. These results indicate that the FLAC-SHWFS provides a practical approach for fast, robust, and large-dynamic-range wavefront measurement.
AB - The Shack-Hartmann wavefront sensor (SHWFS) is widely used for fast, accurate, and stable wavefront measurement, but its dynamic range is limited when focal spots move outside their corresponding subapertures. This paper presents a fiducial-lenslet-anchored clustering SHWFS (FLAC-SHWFS) for robust, large-dynamic-range wavefront measurement. The method combines clustering-based index assignment with fiducial lenslets embedded in the microlens array. Clustering assigns relative row and column indices to the detected spots, while the fiducial spots provide anchors that register these indices to the reference array, enabling reliable global spot-lenslet correspondence beyond local neighborhoods. Simulations show a mode-dependent improvement of the measurable dynamic range, substantial for the low-order Zernike modes Z4 and Z6, but marginal for Z9 and Z10. With the fiducial spot retained and correctly identified, the method achieved successful reconstruction in all 20 trials at each tested random spot-loss probability up to 35 %, and successful matching remained possible in individual trials at 65 % spot loss. The combined computation time of index assignment and morphology-based discrimination is 1.24 ms on average. Experiments using ophthalmic trial lenses verify the large-dynamic-range measurement capability. Further tests under 21.84 % structured spot loss produced by a spider-type aperture stop and 25 % random spot loss generated from a full-aperture spot image maintain reliable global matching, with residual RMS values of 0.159 λ and 0.048 λ, respectively. These results indicate that the FLAC-SHWFS provides a practical approach for fast, robust, and large-dynamic-range wavefront measurement.
KW - Clustering algorithm
KW - Dynamic range
KW - Fiducial lenslet
KW - Global spot matching
KW - Shack-Hartmann wavefront sensor
KW - Spot loss
UR - https://www.scopus.com/pages/publications/105053986604
U2 - 10.1016/j.optlaseng.2026.110188
DO - 10.1016/j.optlaseng.2026.110188
M3 - Article
AN - SCOPUS:105053986604
SN - 0143-8166
VL - 208
JO - Optics and Lasers in Engineering
JF - Optics and Lasers in Engineering
M1 - 110188
ER -