摘要
The optimal working fluid inventory of a prototype of a cryogenic loop heat pipe (CLHP) is studied in this paper. The CLHP prototype operates within a temperature range of 77-126 K with nitrogen as the working fluid. The possible fluid inventory range is calculated based on analysis of phase distribution of vapor and liquid within the loop in a normal operation mode. Furthermore, a series of experiments are carried out with various filling pressures of the gaseous nitrogen at room temperature for validation of the fluid inventory range and identification of the optimal fluid inventory. The experimental results are compared with the calculation results, and the effect of different filling pressure on the performance of the CLHP is analyzed.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 334-337 |
| 页数 | 4 |
| 期刊 | International Journal of Heat and Mass Transfer |
| 卷 | 66 |
| DOI | |
| 出版状态 | 已出版 - 2013 |
| 已对外发布 | 是 |
学术指纹
探究 'Investigation on optimal working fluid inventory of a cryogenic loop heat pipe' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver