TY - JOUR
T1 - Interface Engineering via Self-Assembled Monolayers Enables Highly Sensitive Photomultiplication-Type Organic Photodetectors for Photoplethysmography
AU - Yao, Qi
AU - Ge, Zihao
AU - Li, Shipei
AU - Li, Shaohui
AU - Jin, Kaijia
AU - Qin, Yunke
AU - Zhao, Xingchao
AU - Ma, Xiaoling
AU - miao, Junhui
AU - wang, Feng
AU - Liu, Jun
AU - Zhang, Fujun
AU - Yuan, Guangcai
AU - Yu, Zhinong
N1 - Publisher Copyright:
© 2026 American Chemical Society
PY - 2026/8/11
Y1 - 2026/8/11
N2 - Photomultiplication-type organic photodetectors (PM-OPDs) were fabricated by employing a blend of P3HT and the narrow-band gap small-molecule acceptor FM4. The blend ratio between P3HT and FM4 was optimized to 100:4 (wt/wt). Under –10 V bias, the PM-OPDs based on P3HT:FM4 (100:4, wt/wt) exhibit a spectral response range from 300 to 900 nm with EQE values of 1600% at 625 nm and 850% at 850 nm. This behavior is attributed to hole tunneling injection triggered by trapped electrons. To further improve the sensitivity of PM-OPDs, PEDOT:PSS is replaced by the self-assembled monolayer (SAM) Ph-4PACz as the interfacial layer. The dark current density (JD) of PM-OPDs drops from 2.11 × 10−6 to 4.84 × 10−7 A cm−2, while the light current density (JL) slightly increases by employing Ph-4PACz, resulting in an apparently improved signal-to-noise ratio from 560 to 2700. At –10 V bias, the optimized PM-OPDs deliver EQEs of 1800% (625 nm) and 950% (850 nm), along with specific detectivities (D*shot) of 1.36 × 1013 Jones at 625 nm and 6.31 × 1012 Jones at 850 nm. The optimized PM-OPD-based photoplethysmography PPG sensor enables reliable detection of blood oxygen saturation and heart rate, with measurement discrepancies remaining within 2% when benchmarked against a commercial smartwatch.
AB - Photomultiplication-type organic photodetectors (PM-OPDs) were fabricated by employing a blend of P3HT and the narrow-band gap small-molecule acceptor FM4. The blend ratio between P3HT and FM4 was optimized to 100:4 (wt/wt). Under –10 V bias, the PM-OPDs based on P3HT:FM4 (100:4, wt/wt) exhibit a spectral response range from 300 to 900 nm with EQE values of 1600% at 625 nm and 850% at 850 nm. This behavior is attributed to hole tunneling injection triggered by trapped electrons. To further improve the sensitivity of PM-OPDs, PEDOT:PSS is replaced by the self-assembled monolayer (SAM) Ph-4PACz as the interfacial layer. The dark current density (JD) of PM-OPDs drops from 2.11 × 10−6 to 4.84 × 10−7 A cm−2, while the light current density (JL) slightly increases by employing Ph-4PACz, resulting in an apparently improved signal-to-noise ratio from 560 to 2700. At –10 V bias, the optimized PM-OPDs deliver EQEs of 1800% (625 nm) and 950% (850 nm), along with specific detectivities (D*shot) of 1.36 × 1013 Jones at 625 nm and 6.31 × 1012 Jones at 850 nm. The optimized PM-OPD-based photoplethysmography PPG sensor enables reliable detection of blood oxygen saturation and heart rate, with measurement discrepancies remaining within 2% when benchmarked against a commercial smartwatch.
KW - blood oxygen saturation
KW - near-infrared
KW - organic photodetectors
KW - photomultiplication
KW - self-assembled monolayer
UR - https://www.scopus.com/pages/publications/105047835361
U2 - 10.1021/acsaelm.6c00215
DO - 10.1021/acsaelm.6c00215
M3 - Article
AN - SCOPUS:105047835361
SN - 2637-6113
VL - 8
SP - 6297
EP - 6305
JO - ACS Applied Electronic Materials
JF - ACS Applied Electronic Materials
IS - 15
ER -