跳到主要导航 跳到搜索 跳到主要内容

Insensitivity to humidity in fabry-perot sensor with multilayer graphene diaphragm

  • Cheng Li*
  • , Xiyu Yu
  • , Tian Lan
  • , Jian Liu
  • , Shangchun Fan
  • *此作品的通讯作者
  • Beihang University
  • Science and Technology on Metrology and Calibration Laboratory

科研成果: 期刊稿件文章同行评审

摘要

We developed a novel open-cavity Fabry-Perot (F-P) interferometer with multilayer graphene diaphragm suspended on the endface of a ferrule. The insensitivity to relative-humidity (RH) ranging from 20%RH to 70%RH was investigated in terms of the wavelength shift and power change in interference spectrum, along with the balanced air pressure on both sides of the graphene membrane. The measured wavelength shift of 0.02 nm/%RH and maximum power change of 0.02 dB/%RH demonstrated the humidity-insensitive response of at least one order lower than those for previously reported F-P humidity sensors using porous hydrophilic films. Furthermore, the fitted coupled interaction between dominated temperature and minor humidity yielded a good fitting R-square of about 99.5%. These measurements could shed light on the environmental adaptability of F-P sensors using graphene or other 2-D nanomaterials.

源语言英语
页(从-至)565-568
页数4
期刊IEEE Photonics Technology Letters
30
6
DOI
出版状态已出版 - 15 3月 2018
已对外发布