TY - JOUR
T1 - In-situ visualization of spatiotemporal non-uniform frosting dynamics on refrigerator evaporators under intermittent thermal-moisture shocks
AU - Bai, Xiaoxia
AU - Zhao, Yunzheng
AU - Zhang, Long
AU - Zhang, Xuan
AU - Xie, Teng
AU - Wang, Guoqing
AU - Song, Mengjie
N1 - Publisher Copyright:
Copyright © 2026. Published by Elsevier Ltd.
PY - 2026/10
Y1 - 2026/10
N2 - Intermittent door opening introduces significant thermal and moisture shocks to household refrigerators, severely exacerbating evaporator frosting. However, the dynamic evolution of localized non-uniform frosting under these complex operating conditions remains insufficiently characterized. This study develops a non-invasive in-situ visualization system equipped with anti-condensation technology to quantitatively investigate the spatiotemporal non-uniform frosting characteristics on a fin-and-tube evaporator under periodic door openings. Experimental results reveal that periodic moisture load surges significantly enhance frost accumulation, resulting in a distinct S-shaped frost thickness distribution along the airflow direction. While transverse uniformity within fin rows remains relatively stable, the global longitudinal frost uniformity coefficient (FUC) heavily degrades to 70%–77% under prolonged door opening and high humidity conditions. Furthermore, despite exhibiting thinner individual frost layers, the downstream region with the smallest fin spacing experiences the most severe localized flow-passage constriction, reaching a blockage ratio of 43%–50%. This localized blockage is accompanied by a marked deterioration in system performance, with the air-side pressure drop increasing from less than 7 Pa under the closed-door condition to over 16 Pa under the most severe frosting condition, while the average system power increases by nearly 30%, from 106.32 W to 137.47 W. These findings establish a direct link between spatial frost distribution, geometry-dependent blockage, and refrigerator performance, providing an experimental basis for identifying critical frosting regions and developing zonal and on-demand defrosting strategies.
AB - Intermittent door opening introduces significant thermal and moisture shocks to household refrigerators, severely exacerbating evaporator frosting. However, the dynamic evolution of localized non-uniform frosting under these complex operating conditions remains insufficiently characterized. This study develops a non-invasive in-situ visualization system equipped with anti-condensation technology to quantitatively investigate the spatiotemporal non-uniform frosting characteristics on a fin-and-tube evaporator under periodic door openings. Experimental results reveal that periodic moisture load surges significantly enhance frost accumulation, resulting in a distinct S-shaped frost thickness distribution along the airflow direction. While transverse uniformity within fin rows remains relatively stable, the global longitudinal frost uniformity coefficient (FUC) heavily degrades to 70%–77% under prolonged door opening and high humidity conditions. Furthermore, despite exhibiting thinner individual frost layers, the downstream region with the smallest fin spacing experiences the most severe localized flow-passage constriction, reaching a blockage ratio of 43%–50%. This localized blockage is accompanied by a marked deterioration in system performance, with the air-side pressure drop increasing from less than 7 Pa under the closed-door condition to over 16 Pa under the most severe frosting condition, while the average system power increases by nearly 30%, from 106.32 W to 137.47 W. These findings establish a direct link between spatial frost distribution, geometry-dependent blockage, and refrigerator performance, providing an experimental basis for identifying critical frosting regions and developing zonal and on-demand defrosting strategies.
KW - Door opening
KW - In-situ visualization
KW - Non-uniform frosting
KW - Refrigerator evaporator
KW - Thermal-dynamic performance
UR - https://www.scopus.com/pages/publications/105050470784
U2 - 10.1016/j.applthermaleng.2026.133155
DO - 10.1016/j.applthermaleng.2026.133155
M3 - Article
AN - SCOPUS:105050470784
SN - 1359-4311
VL - 307
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
M1 - 133155
ER -