跳到主要导航 跳到搜索 跳到主要内容

Impact of CCD camera SNR on polarimetric accuracy

  • Zhenyue Chen
  • , Xia Wang
  • , Shaun Pacheco
  • , Rongguang Liang*
  • *此作品的通讯作者

科研成果: 期刊稿件文章同行评审

摘要

Acomprehensive charge-coupled device (CCD) camera noise model is employed to study the impact ofCCD camera signal-to-noise ratio (SNR) on polarimetric accuracy. The study shows that the standard deviations of the measured degree of linear polarization (DoLP) and angle of linear polarization (AoLP) are mainly dependent on the camera SNR. With increase in the camera SNR, both the measurement errors and the standard deviations caused by the CCD camera noise decrease. When the DoLP of the incident light is smaller than 0.1, the camera SNR should be at least 75 to achieve a measurement error of less than 0.01. When the input DoLP is larger than 0.5, a SNR of 15 is sufficient to achieve the same measurement accuracy. An experiment is carried out to verify the simulation results.

源语言英语
页(从-至)7649-7656
页数8
期刊Applied Optics
53
32
DOI
出版状态已出版 - 10 11月 2014
已对外发布

指纹