摘要
Identification of thermal process is important for obtaining the thermal parameters of electric double layer capacitors. This study applies distribution of relaxation times (DRT) analysis for physical interpretation of the thermal impedance spectroscopy measurement of EDLC systems. Three distinct peaks are observed in the DRT plots of the electrode systems. The peak area represents the thermal resistance contribution of different thermal processes, while the time constant of peak center represents the speed of each process. The results indicate that the peaks from short to long time constant can be attributed to heat conductions in solid, interfacial, and fluid-involved paths, respectively. In addition, the area of peaks are strongly affected by the compression of electrode. This is attributed to the variations in total thickness and cross-sectional area of the system. Finally, replacing the fluid from air to electrolyte or changing solid–fluid ratio in two-phase region can lead to a remarkable shift in time constant of fluid-involved heat transfer peak.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 107152 |
| 期刊 | Journal of Energy Storage |
| 卷 | 64 |
| DOI | |
| 出版状态 | 已出版 - 1 8月 2023 |
联合国可持续发展目标
此成果有助于实现下列可持续发展目标:
-
可持续发展目标 7 经济适用的清洁能源
指纹
探究 'Identification of thermal process of electric double layer capacitor systems by distribution of relaxation times analysis for thermal impedance spectroscopy' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver