跳到主要导航 跳到搜索 跳到主要内容

Highly accelerated free-breathing real-time phase contrast cardiovascular MRI via complex-difference deep learning

  • Hassan Haji-Valizadeh
  • , Rui Guo
  • , Selcuk Kucukseymen
  • , Amanda Paskavitz
  • , Xiaoying Cai
  • , Jennifer Rodriguez
  • , Patrick Pierce
  • , Beth Goddu
  • , Daniel Kim
  • , Warren Manning
  • , Reza Nezafat*
  • *此作品的通讯作者

科研成果: 期刊稿件文章同行评审

摘要

Purpose: To develop and evaluate a real-time phase contrast (PC) MRI protocol via complex-difference deep learning (DL) framework. Methods: DL used two 3D U-nets to separately filter aliasing artifact from radial real-time velocity-compensated and complex-difference images. U-nets were trained with synthetic real-time PC generated from electrocardiograph (ECG) -gated, breath-hold, segmented PC (ECG-gated segmented PC) acquired at the ascending aorta of 510 patients. In 21 patients, free-breathing, ungated real-time (acceleration rate = 28.8) and ECG-gated segmented (acceleration rate = 2) PC were prospectively acquired at the ascending aorta. Hemodynamic parameters (cardiac output [CO], stroke volume [SV], and mean velocity at peak systole [peak mean velocity]) were measured for ECG-gated segmented and DL-filtered synthetic real-time PC and compared using Bland-Altman and linear regression analyses. Additionally, hemodynamic parameters were quantified from DL-filtered, compressed-sensing (CS) -reconstructed, and gridding reconstructed prospective real-time PC and compared to ECG-gated segmented PC. Results: Synthetic real-time PC with DL showed strong correlation (R > 0.98) and good agreement with ECG-gated segmented PC for quantified hemodynamic parameters (mean-difference: CO = −0.3 L/min, SV = −4.3 mL, peak mean velocity = −2.3 cm/s). On average, DL required 0.39 s/frame to filter prospective real-time PC, which was 4.6-fold faster than CS. Compared to CS, DL showed superior correlation, tighter limits of agreement (LOAs), better bias for peak mean velocity, and worse bias for CO and SV. Compared to gridding, DL showed similar correlation, tighter LOAs for CO and SV, similar bias for CO, and worse bias for SV and peak mean velocity. Conclusion: The complex-difference DL framework accelerated real-time PC-MRI by nearly 28-fold, enabling rapid free-running real-time assessment of flow hemodynamics.

源语言英语
页(从-至)804-819
页数16
期刊Magnetic Resonance in Medicine
86
2
DOI
出版状态已出版 - 8月 2021
已对外发布

指纹

探究 'Highly accelerated free-breathing real-time phase contrast cardiovascular MRI via complex-difference deep learning' 的科研主题。它们共同构成独一无二的指纹。

引用此