Heating performance of heat pump air conditioning system with scroll and swash plate compressor

  • Beijing Institute of Technology

科研成果: 期刊稿件文章同行评审

摘要

The effects of the scroll compressor and the variable displacement swash plate compressor on the average temperature in the electric vehicle cabin and the performance of the heat pump air conditioning system were studied under different environment temperature. The experiments were carried out on an experiment platform designed for the heat pump air conditioning system of electric vehicle. The research results show that the average temperature in the cabin increases with time along the rightwards parabolic curve when the heat pump air conditioning system makes use of the variable displacement swash plate compressor, and the temperature increases with time along the upwards parabolic curve when the heat pump air conditioning system makes use of the scroll compressor. At the constant ambient temperature, the cabin comfortable temperature achieves in less time with the increasing of the compressor rotation speed.

源语言英语
页(从-至)13-18
页数6
期刊Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology
36
1
DOI
出版状态已出版 - 1 1月 2016